140 °F(60 °C), or incinerate. Replace the Installation and operation manual battery with a Dometic battery of the same model only. The use of an- other battery may present a risk of fire or explosion. • Do not connect the battery directly to AC power.
EN 7 Technical description Components The 100 Ah battery has the following components: The advanced LiFePO4 battery offers the desired features like charging below freez- ing, series connected batteries as well as BLE and CANBUS connectivity. The battery is equipped with a Battery Management System (BMS) that is built in the battery housing.
EN 8 Installation Mounting the battery 100Ah 300Ah Mount the battery either in vertical or upright position with the screws and the mounting bracket to a wall. Do not mount the battery on the wall without the mounting bracket. Do not mount the battery on the wall with mounting bracket in horizontal posi- tion.
Page 7
EN The LED indicator turns on. Using the Advanced Lithium app Download the Go Power Connect! app. 8. Press system to run the main functionalities. Load Monitor the battery voltage, DC current, power, Ah remaining, time remaining, charge state, and battery temperature. ...
Battery cannot charge Protection against over volt- Disconnect the charg- In such a case Dometic products found to be defective and covered by this warranty, age protection er and load discharge Protection against over cur- current for few min- will be replaced at Dometic' option, and returned to the customer.
Page 9
EN Prior to returning product to Dometic under warranty, please obtain a Return Goods Authorization number (claim number). Be sure to label the goods with: a) the name and address of the sender, and b) the return goods authorization number (claim number) Please address the returned goods as follows: From U.S.A.
EN 15 Technical data NOTE In the table below all values are minimum performance values and “must have” unless indicated otherwise. 100 Ah 300 Ah Nominal voltage 12.8 V Nominal capacity 100 Ah 300 Ah Cycle life 3000-5000 cycles Charge Charging temperature range -20 °C …...
Page 11
EN 100 Ah 300 Ah Long term storage If the battery needs to be stored for > 3 months the voltage should be 13.2 V(50 %SOC), and stored at the storage specifications shown above. Additionally, the battery needs at least one charge and discharge cycle every six months. Cell ≥...
Page 12
EN Min cell temp ≥ 5 °C Low temperature alarm clear Discharge current alarm Discharge current > 130 A Remaining capacity < 7 Ah OR min cell voltage ≤ 2500 mV Discharge current alarm clear Discharge current < 100 A Low SOC alarm Remaining capacity ≥...