Dometic GP-ADV-LIFEPO4-100 Installation And Operating Manual page 15

Hide thumbs Also See for GP-ADV-LIFEPO4-100:
Table of Contents

Advertisement

 
High temperature alarm clear
Low temperature alarm
Low temperature alarm clear
Discharge current alarm
Discharge current alarm clear
Low SOC alarm
Low SOC alarm clear
LED
Reserve mode
Communication
Capacitor pre-charge
Heater control
auto
enabled
disabled
100 Ah
charge mode:
min cell temp<3 °C
min cell temp>=5 °C
discharge current>130 A
discharge current<100 A
remaining capacity <7 AhOR min cell voltage<=2500 mV
remaining capacity >=7 Ah OR min cell voltage>=2800 mV
power ON mode
sleep mode
power OFF mode
enter reserve mode
exit reserve mode
CANbus and BLE
battery pack has a pre-charge function to charge bulk capacitors in inverters to avoid surge current
ON
OFF
ON
OFF
always OFF
300 Ah
cell max temp>=57 °Cor
MOSFET temp>=105 °C
cell max temp<=55 °Cor
MOSFET temp<=90 °C
LED solid
LED blink
LED off
battery remain capacity < 5 Ah OR min cell voltage <2.5 V
pack SOC>5 Ah AND min cell voltage >=2.5 V AND
charging OR button pressed for 3 s
protocol: RV-C with baud rate 250Kbs
1) If cell temperature 0 °C<T<2 °C, battery is in power ON
mode and pack terminal voltage >=13.8 V or charging cur-
rent >10 A
2) If cell temperature T<0 °C, battery is in power ON mode
and pack terminal voltage >=13.8 V
3) If cell temperature T<2 °C and battery is in sleep mode,
heater always ON
1) If cell temperature T<2 °C, battery is in power ON mode
and pack terminal voltage <=13.5 V or discharge current
for 10 s
2) If cell temperature T>=7 °C and battery is in power ON
mode or sleep mode
If cell T<2 °C
If cell T>7 °C
EN