Dometic GP-ADV-LIFEPO4-100 Installation And Operating Manual page 14

Hide thumbs Also See for GP-ADV-LIFEPO4-100:
Table of Contents

Advertisement

EN
Long term storage
If the battery needs to be stored for > 3 months the voltage should be 13.2 V(50 %SOC), and stored at the storage specifications
shown above. Additionally, the battery needs at least one charge & discharge cycle every six months.
BMS
Balancing
Current
Over charge protection
Over discharge protection
BMS shutdown
Charge over current protection
Discharge over current protection
Charge over temperature protection
Discharge over temperature protection
FET over temperature protection
Single cell high voltage alarm
Single cell low voltage alarm
High temperature alarm
14
100 Ah
balance start voltage
balance start voltage difference
balance off voltage difference
charge balance current for single cell
self-discharge current (active mode)
self-discharge current (shutdown mode)
max charge/discharge current
over charge protection voltage
over charge protection delay time
over charge release voltage
over discharge protection voltage
over discharge protection delay
over discharge release voltage
shutdown voltage
shutdown time
recovery
charge over current protection current
charge over current protection delay
over charging current protection release
discharge over current protection current (1)
discharge over current protection delay (1)
over current release
discharge over current protection current (2)
discharge over current protection delay (2)
over current release
discharge over current protection current (3)
discharge over current protection delay (3)
over current release
charge high temperature protection
charge high temperature release
charge low temperature protection
charge low temperature release
discharge high temperature protection
discharge high temperature release
FET high temperature protection
FET high temperature release
cell high voltage alarm when
alarm clear when
cell low voltage alarm when
alarm clear when
discharge mode:
300 Ah
cell≥ 3380 mV
≥50 mV
≤30 mV
≤ 40 mA
40 mA ... 50 mA
≤20 μA
100 A/100 A
3.8 V±0.02 V/cell
2 s
3.6 V±0.02 V/cell
2.3 V±0.1 V/cell
2 s
min cell voltage recover to 2.8 V±0.1 Vand charging
min cell voltage <=2250mV
delay 120 s
charging or press button
120 A±5 A
2 s
auto recover after waiting 30 s
150 A±5 A
10 s
auto recover after waiting 30 s
250 A±5 A
5 s
auto recover after waiting 30 s
450 A±5 A
500 ms
auto recover after waiting 30 s
>60±3 °C
<55±3℃
<0±3 °C
>5±3 °C
>80±3 °C
<61±3 °C
>110±3 °C
<90±3 °C
max cell >=3750 mV
max cell <=3600 mV
min cell <=2500 mV
min cell >=2800 mV
cell max temp>=75 °Cor
MOSFET temp>=105 °C
 

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gp-adv-lifepo4-300

Table of Contents