Basic Test Procedure
Figure 12. ADS58H40 11-bit SNRBoost Mode, Single Tone Test Result: Fs = 245.76 MSPS, Fin = 170 MHz
Single tone FFT test (ADS58H40 14-bit High Resolution Burst Mode)
1. Select the ADS58H40-14b device.
2. After selecting Single Tone FFT Test under Test Selection, enter the sample rate, input frequency, and
the number of samples.
3. Select channel A, B, C, or D depending on which channel is connected to the signal generator.
4. On the High Speed Data Converter Pro menu, select Data Capture Options → Trigger Option. Check
both Trigger Mode Enable and Software Trigger Enable.
14