Mitsubishi Electric PUMY-P36NKMU4 Technical & Service Manual page 121

Hide thumbs Also See for PUMY-P36NKMU4:
Table of Contents

Advertisement

Outdoor power circuit board
PUMY-P60NKMU4
PUMY-HP36NKMU2
PUMY-HP42NKMU2
PUMY-HP48NKMU2
TB3, TB4
Voltage of 208/230 V AC
is input
(Connect to the outdoor
noise filter board (TB1,
TB2))
TB1A, TB2A, TB3A,
TB1B, TB2B, TB3B
Connect to DCL
CNDC
290–380 V DC ( +,
−)
Connect to the outdoor
multi controller circuit
board (CNDC)
OCH811A
Brief Check of POWER MODULE
If they are short-circuited, it means that they are broken.
Measure the resistance in the following points (connectors, etc.).
1. Check of POWER MODULE
Check of DIODE circuit
R - L1 , S - L1 , R - N1 , S - N1
Check of IGBT circuit
L2 - N1
Check of INVERTER circuit
P - U , P - V , P - W , N1 - U , N1 - V , N1 - W
Note: The marks R , S , L1 , L2 , P , N1 , U , V and W shown
in the diagram are not actually printed on the board.
N2
L2
P2
N3
L3
L1
121
CN4
Connect to the outdoor
multi controller circuit
board (CN4)
CN2
Connect to the outdoor
multi controller circuit
board (CN2)
– : Transmitting sig-
V
P3
– : Zero cross signal
W
U
– : 15 V DC
– : 15 V DC
– : 15 V DC
TB-U, TB-V, TB-W
Connect to the compres-
sor (MC)
Voltage among phases:
10-180 V AC
CN6
Thermistor (TH8)
nal to outdoor
controller circuit
board ((0–5 V
DC)
(0–5 V DC)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents