3

SPECIFICATIONS

Service Ref.
Indoor type
Capacity Rated *
1
Rated power consumption *
1
Current input (208/230V)
EER2
SEER2
Capacity Rated 47°F *
1
Capacity Max. 17°F *
2
Capacity Max. 5°F
Rated power consumption 47°F *
Current input (208/230V)
COP 47°F *
1
HSPF2
/
Power supply
Breaker Size/Maximum over current protection
Minimum circuit ampacity
Indoor unit
Total capacity
Model/Quantity *
connectable
Sound pressure level
(measured in anechoic room)
Refrigerant
Liquid pipe
piping diameter
Gas pipe
Fan
Type × Quantity
Airflow rate
Control, Driving mechanism
Motor output
External static press.
Compressor
Type × Quantity
Manufacture
Starting method
Motor output
Case heater
Lubricant
External finish
External dimension H × W × D
Protection
High pressure protection
devices
Inverter circuit (COMP./FAN)
Compressor protection
Fan motor protection
Refrigerant
Type × original charge
Control
Net weight
Heat exchanger
HIC circuit (HIC: Heat Inter-Changer)
Defrosting method
Guaranteed operation range
Remarks
* 1 Rating conditions
Cooling Indoor
Outdoor : D.B. 95°F [D.B. 35.0°C]
Heating Indoor
Outdoor : D.B. 47°F/W.B. 43°F [D.B. 8.3°C/W.B. 6.1°C]
* 2 Conditions
Heating Indoor
Outdoor : D.B. 17°F/W.B. 15°F [D.B. −8.3°C/W.B. −9.4°C]
*3 It cannot be connected mixed CITY MULTI indoor unit and branch box indoor unit.
*4 D.B. 5 to 115°F [D.B. -15 to 46°C], when an optional Air Outlet Guide is installed.
However, this condition does not apply to the indoor units listed in *5.
*5 50 to 115°F (10 to 46°C) D.B.: When connecting PKFY-P04/06/08/12NLMU, PFFY-P06/08/12NEMU, and PFFY-P06/08/12NRMU type indoor unit.
*6 When the temperature is below D.B. 50°F [D.B. 10°C] with branch box system, noise could potentially occur.
Note: Refer to the indoor unit's service manual for the indoor units specifications.
OCH811A
Non-Ducted
Btu/h
36,000
W
2,400
A
11.7/10.6
Btu/h/W
15.00
-
23.00
Btu/h
41,000
Btu/h
36,000
Btu/h
29,000
1
W
3,005
A
14.7/13.3
W/W
4.00
-
11.00/8.75
3
CITY MULTI
Branch box
dB <A>
inch (mm)
inch (mm)
m³/min
L/s
cfm
kW
kW
kW
mm
inch
lb (kg)
(Cooling)
(Heating)
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and
other items shall be referred to the Installation Manual.
Due to continuing improvement, above specifications may be subject to change without notice.
: D.B. 80°F/W.B. 67 °F [D.B.26.7°C/W.B. 19.4°C]
: D.B. 70°F [D.B. 21.1°C]
: D.B. 70°F [D.B. 21.1°C]
PUMY-P36NKMU4
Mix
Ducted
36,000
36,000
2,740
3,190
13.4/12.1
15.6/14.1
13.15
11.30
19.30
15.60
41,000
41,000
36,000
36,000
29,000
29,000
3,250
3,535
15.9/14.3
17.3/15.6
3.70
3.40
9.80/8.05
8.60/7.40
1-phase 208/230 V, 60 Hz
30 A/64 A (When power is supplied separately)
40 A/70 A (When power is supplied from the outdoor unit)
36 A (When power is supplied separately)
42 A (When power is supplied from the outdoor unit)
50 to 130% of outdoor unit capacity
04 - 36/11
06 - 36/4
49/53
3/8 (ø9.52)
5/8 (ø15.88)
Propeller fan × 2
DC control
0.074 × 2
Scroll hermetic compressor x 1
Mitsubishi Electric Corporation
2.8
FV50S 78oz. (2.3L)
Galvanized Steel Sheet <Munsell 3Y 7.8/ 1.1>
1,338 × 1,050 × 330 (+25)
52-11/16 × 41-11/32 × 13 (+1)
High pressure switch
Overcurrent detection, Overheat detection (Heat sink thermistor)
Compressor thermo, Overcurrent detection
Overheating/Voltage protection
R410A 10 lbs. 9 oz. (4.8kg)
Linear Expansion Valve
271 (123)
Cross fin and tube
HIC circuit
Reversed refrigerant circuit
D.B 23 to 115°F [ D.B.-5 to 46°C ] * 4 * 5 * 6
D.B.-13 to 70°F [D.B. -25 to 21°C ]
11
PUMY-P48NKMU4
Mix
Non-Ducted
48,000
48,000
3,665
4,090
17.9/16.2
20.0/18.1
13.10
11.75
23.00
18.85
50,000
50,000
43,000
43,000
35,400
35,400
3,665
4,075
17.9/16.2
19.9/18.0
4.00
3.60
10.40/8.35
9.35/7.90
04 - 54/12
06 - 36/8
51/54
110
1,834
3,885
0
Inverter
3.4
0
kcal/h = kW o 860
Btu/h = kW o 3412
Conversion formula:
CFM
Ducted
48,000
4,615
22.5/20.4
10.40
14.70
50,000
43,000
35,400
4,580
22.4/20.2
3.20
8.30/7.50
/min o 35.31
= m
3

Hide quick links:

Advertisement

Table of Contents
loading