The temperature is not cold enough
(Continued)
Electrical Shock
Noise
Extreme condensation inside the
refrigerator
17
The refrigerator has been
overcharged with the refrigerant gas
The refrigerant gas is leaking
The evaporator and/or condenser
fans are not working
Blocking air flow
Fuse blown or circuit breaker tripped Replace fuse or reset circuit breaker
Wires or electrical components are
in direct contact with metallic parts
The refrigerator is not properly
levelled
The condenser is not fastened
correctly. Copper tubing is in contact
with metal
The evaporator and/or condenser
fans are loose
Compressor has an internal noise
Loose part(s)
Controller is set at a very cold
position
The outside environment's relative
humidity is very high (over 75%)
The refrigerator door won't shut
completely
The refrigerator had been placed at
an inadequate location
Check to see if condensation or ice
crystals have formed on the suction
line. If so, charge with the correct
amount of gas
Find the location of gas leak in order to
seal and replace the defective
component. Change the drier. Perform
a good vacuum and recharge unit
Check electrical connections and make
sure that the fan blade isn't stuck.
Replace the fan motor if it doesn't
work.
Re-arrange product to allow for proper
air flow. Make sure there is at least four
inches of clearance from the
evaporator.
Check for appropriate insulation on the
connections of each component
Check if the noise goes away after you
level the refrigerator
While the compressor is working, check
to see if metal parts are in contact with
one another and/or if the screws that
fasten the condenser are tightened
Check if the fans are securely
fastened. Also, check if the fan blades
are loose, broken or cracked. If so,
change the faulty blade
If the noise persists after all other
measures have been taken, it may be
originating from the compressor.
Locate and tighten loose part(s)
Set the controller to a warmer
position & check to see if compressor
stops as should
This type of occurrence is caused by
local climatic conditions and not by the
refrigeration unit
Check the door and/or the magnetic
gasket. Adjust the door hinges if
needed; replace the gasket if broken
The unit must not be near sources that
produce too much heat