ELECTRICAL FEEDER CABLE CONNECTION
WARNING: The power supply cable must be connected only by an authorised service
agent in order to avoid a hazard.
If the power supply cable is damaged, it must be replaced only by an authorised
service agent in order to avoid a hazard.
To connect the supply cable:
Unhook the terminal board cover by inserting a screwdriver into the two hooks "A" (fig. 11.1).
Unscrew the screw "D" and open completely the cable clamp "E" (fig. 11.2).
Connect the phase, neutral and earth wires to terminal board "G" according to the
diagram in fig. 11.3.
Strain the feeder cable and block it with cable clamp "E" (by screwing screw "D") .
Close the terminal block cover (check the two hooks "A" are correctly hooked) .
NOTE: The earth conductor must be left about 3 cm longer than the others.
IMPORTANT: To connect the power supply cable DO NOT unscrew the screws fixing
the cover plate behind the terminal block.
POWER SUPPLY
230 V
50 Hz
FEEDER CABLE SPECIFICATIONS
Type "H05RR-F" or "H05VV-F"
3 x 2,5 mm
2
Fig. 11.1
48
4300 W
A
L1
N
L2
PE
D
230 V 50 Hz
230 V 50 Hz
1
G
2
3
4
5
E
Fig. 11.2
L
N
PE
Fig. 11.3