Page 1
Operation Manual Remote Amplifier with Zone Selector RM-6016...
Page 2
A personal welcome to you from the management and employees of Inter-M All of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value, and we are delighted you have purchased one of our products.
REMOTE AMPLIFIER with ZONE SELECTOR Contents Contents Unpacking ............................2 Installation Environment............................2 Important Safety Instructions......................2 Features ............................3 Operation ............................3 Front Panel ............................4 Suggestions for Rack Installation ....................7 Applications ............................8 Block Diagram ..........................9 Specifications ..........................10 Service Procedures............................11 Schematic.............................11 Parts List ............................11 Warranty ............................11 RM-6016...
REMOTE AMPLIFIER with ZONE SELECTOR Unpacking Unpacking Although your RM-6016 is neither complicated nor difficult to operate, we recommend you take a few minutes to read this brief manual and familiarize yourself with the important information regarding product features, setup and operation.
Four tone pre-announcement chime, activated by push button CHIME switch. - OUTPUT LEVEL METER Ten segment LED bar graph on the front panel that indicates instantaneous signal output level of the RM-6016. - MIC BROADCASTING Easy to use, highly sensitive condenser type MIC for clear broadcasting.
Switches ON/OFF the 24V DC power source. 6. AUX VOLUME Turn to the right to increase the volume and to the left to decrease the volume. 7. CHIME VOLUME Turn to the right to increase the volume and to the left to decrease the volume. RM-6016...
Page 7
13. ALL CALL SWITCH This switch, when pressed ON, selects all the sixteen loudspeaker zones for the broadcast. 14. TALK LED Visual indication of the TALK ON switch. 15. TALK SWITCH The TALK ON switch activates for the MIC (LED ON). RM-6016...
Page 8
REMOTE AMPLIFIER with ZONE SELECTOR 1. Connector Section 1. SPEAKER CONTROL & COM TERMINALS Connect these speaker control line terminals to the Remote 1 or Remote 2 inputs of the Inter-M PX-6116 matrix unit. 2. 24V DC POWER INPUT TERMINALS Connect the 24V DC output of the Inter-M power distributor PD-6359 to these terminals.
1. Ensure that power is switched off before installation and before any wiring is connected to the equipment. 2. Site the equipment in well ventilated places and avoid places of high humidity. 3. Whenever possible, fit Inter-M MIC model CM-916. If a Phantom powered MIC is to be used, we recommend that it operates on +5V DC.
REMOTE AMPLIFIER with ZONE SELECTOR Specifications Specifications RM-6016 Output Level 1.2V ±200mV, BAL -60dB/600Ω, BAL Input Sensitivity/Impedance -20dB/10kΩ, UNBAL 100Hz ~ 15kHz Frequency Response (±3dB) 80Hz ~ 18kHz Less than 0.5% T.H.D Less than 0.3% Batter than 47dB Batter than 50dB Speaker Control Terminal &...
To obtain specific warranty information and available service locations contact Inter-M directly or the authorized Inter-M Distributor for your specific country or region.
Page 16
Inter-M, Ltd. (Korea) began operations in 1983. Since then, Inter-M has grown to become one of the largest manufacturers of professional audio and commercial sound electronics equipment in the world. Inter-M has gained worldwide recognition for its own branded products, as well as private label manufacturing of electronics sold under other names (OEM).