Omron NT20S-ST121B-EV3 User Manual page 199

Programmable terminal
Table of Contents

Advertisement

Memory Tables and Bar Graphs
Setting the Words of the Character-String Memory Table
Symbol
C-series
None
IR Area
H
HR Area
A
AR Area
L
LR Area
T
TC Area
Timer PVs
TU
---
C
TC Area
Counter PVs
CU
---
W
---
TK
---
D
DM Area
E
EM Area
(See note 2.)
E0_to EC_
---
Note
Displaying and Referencing Numeral Memory Table Contents
178
When creating the screen data by using the Support Tool, make the following
settings for each numbered character string:
• Initialization Setting
Set whether or not the PLC words are initialized with the character-string
memory table initial value registered to the screen data memory when the
main power supply is turned ON or reset.
• Number of Registration Words
Set the number of words within 16 words required for registering the char-
acter-string data. One word can store two normal-size characters.
• Setting the Words for the Character-string Memory Table Entries
The character-string memory table entries can be allocated to the following
PLC words. Set the word type and the first word.
Alloca-
CVM1/CV -series
tion
CIO Area
---
AR Area
---
×
TC Area
Timer PVs
---
---
×
TC Area
Counter PVs
---
---
---
---
---
---
DM Area
EM Area
Current bank
---
---
Since the AR area bits of the CVM1/CV-series PLCs are allocated to the sys-
tem, they cannot be used for purposes other than the system use.
If the "number of registration words x 2" ("word setting window") set with the
Support Tool is larger than the "number of character digits" ("character-string
display setting" window), the character string may be broken halfway.
(1) LR 00000 to LR 00199 are converted to CIO 01000 to CIO 01199.
(2) The EM Area is supported only by the C200HX/HG/HE-(Z)E PLCs.
Since the numeral memory table entries can be allocated to the words in the
PLC, the PLC can write data to the numeral memory table entries or the initial
values can be set when creating the screen data.
Alloca-
CS/CJ-series
tion
CIO Area
---
HR Area
×
AR Area
---
LR Area (See note 1.)
×
TC Area
Timer PVs
---
TC area,
Timer Completion Flags
×
TC Area
Counter PVs
---
TC area,
Counter Completion Flags
---
WR
---
Task Flags
DM Area
Not for
EM Area
Host Link
Current bank
---
EM Area
EM bank 0 to C
Section 5-2
Alloca-
tion
Not for
Host Link
Not for
Host Link
×
×
×
×
Not for
Host Link
×
Not for
Host Link
Not for
Host Link
❍: OK × : NG

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nt20Nt series

Table of Contents