Omron NT20S-ST121B-EV3 User Manual page 196

Programmable terminal
Table of Contents

Advertisement

Overview of Direct Connection Operations
Symbol
C-series
None
IR Area
H
HR Area
A
AR Area
L
LR Area
T
TC Area
Timer PVs
TU
---
C
TC Area
Counter PVs
CU
---
W
---
TK
---
D
DM Area
E
EM Area
(See note 2.)
E0_to EC_
---
Note
1,2,3...
Currently Displayed Screen and PT Status Words in the PT Status Notify
Area
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit
Word
Screen number (4-digit BCD)
m
PT status
m+2
15 14 13 12 11 10 9 8 Bit
-
0
0
Screen number: 0001 to 0500
Use a 4-digit BCD (binary-coded decimal) value to set a screen number.
The screen switch strobe bit reverts to OFF (0) after the PLC is notified.
• Available Allocation Words
The PT status notify area (PT to PLC) can be allocated to the following
PLC areas.
Alloca-
CVM1/CV -series
tion
CIO Area
---
AR Area
---
×
TC Area
Timer PVs
---
---
×
TC Area
Counter PVs
---
---
---
---
---
---
DM Area
EM Area
Current bank
---
---
Since the AR area bits of the CV-series PLCs are allocated to the system,
they cannot be used for purposes other than the system use.
The range of respective area varies with the type of PLC.
(1) LR 00000 to LR 00199 are converted to CIO 01000 to CIO 01199.
(2) The EM Area is supported only by the C200HX/HG/HE-(Z)E.
1. Use the Support Tool to allocate the PT status notify area (PT to PLC) to
the PLC memory.
Screen switch setting
PT status
0
0
-
0
0
0
Screen switch strobe
Alloca-
CS/CJ-series
tion
CIO Area
---
HR Area
×
AR Area
---
LR Area (See note 1.)
×
TC Area
Timer PVs
---
TC area,
Timer Completion Flags
×
TC Area
Counter PVs
---
TC area,
Counter Completion Flags
---
WR
---
Task Flags
DM Area
Not for
EM Area
Host Link
Current bank
---
EM Area
EM bank 0 to C
Section 5-1
Alloca-
tion
Not for
Host Link
Not for
Host Link
×
×
×
×
Not for
Host Link
×
Not for
Host Link
Not for
Host Link
❍: OK × : NG
175

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nt20Nt series

Table of Contents