Type 6020
Installation
5.3
Installation of socket variants
Fig. 6: Installation of socket variants
Note flow direction: see data sheet
Ensure that the seal surfaces on the body port connections are free of any damage.
Hold the device on the valve body using an open-end wrench and screw into the pipeline.
NOTICE!
Be sure not to damage the seal surfaces on the body port connections when screwing into the pipeline.
5.4
Cartridge variant installation
Fig. 7: Installation of cartridge variants, example FC17
Ensure that the O-rings on the valve body and the seal surfaces of the connection housing are free of
any damage.
Recommendation:coat O-rings on the body in a suitable lubricant to prevent damage.
Press the valve into the connection housing.
Tightly screw in the retaining plate crosswise, observing the tightening torque indicated in the following
table.