SECTION 10 − TROUBLESHOOTING
10-1. Welding Troubleshooting
Trouble
Low or no weld output; generator pow-
er output okay at ac receptacles.
No weld output or generator power out-
put at ac receptacles.
Low weld output.
High weld output.
Erratic weld output.
10-2. Generator Power Troubleshooting
Trouble
No or low generator power output at ac
receptacles; weld output okay.
receptacles; weld output okay
Check control settings.
Check weld connections.
Check fuse F1, and replace if open (see Section 8-4 or 9-6).
Have Factory Authorized Service Agent check brushes, slip rings, capacitor C1, and integrated rectifi-
ers SR2 and SR3.
Be sure all equipment is disconnected from receptacles when starting unit.
Check fuses F1 and F2, and replace if open (see Section 8-4 or 9-6).
Check plug PLG6 connection.
Have Factory Authorized Service Agent check brushes, slip rings, capacitor C1, and integrated rectifi-
ers SR2 and SR3.
Check fuse F1, and replace if open (see Section 8-4 or 9-6).
Check control settings.
Check engine speed, and adjust if necessary (see Section 8-6 or 9-5).
Service air cleaner according to engine manual.
Have Factory Authorized Service Agent check brushes, slip rings, capacitor C1, and integrated rectifi-
ers SR2 and SR3.
Check control settings.
Check engine speed, and adjust if necessary (see Section 8-6 or 9-5).
Check control settings.
Tighten and clean connections to electrode and workpiece.
Use dry, properly-stored electrodes for Stick and TIG welding.
Remove excessive coils from weld cables.
Clean and tighten connections both inside and outside welding generator.
Check engine speed, and adjust if necessary (see Section 8-6 or 9-5).
Have Factory Authorized Service Agent check brushes, slip rings, and integrated rectifiers SR2, SR3.
Reset circuit breakers (see Section 7-1 or 7-2).
Press optional GFCI receptacle Reset button (see Section 7-2).
Check fuse F2, and replace if open (see Section 8-4 or 9-6).
Check plug PLG6 connection.
Have Factory Authorized Service Agent check brushes, slip rings, and integrated rectifier SR3.
Remedy
Remedy
OM-4434 Page 39