6-9. High-Frequency Board PC7 Testing Information (Use with Section 6-10)

3
2
TM-357 Page 32
1
Y Discharge input capacitors
according to Section 7-5,
and be sure voltage is near
zero before touching any
parts.
Be sure plugs are secure before
testing. See Section 6-10 for
specific values during testing.
1
High-Frequency Board PC7
2
Receptacle RC1
3
Receptacle RC2
4
Receptacle RC3
5
Receptacle RC4
6
Spark Gap—Set At 0.010 in
(0.254 mm)
4
5
6
Test Equipment Needed:
ST-802 035 / SC-186 808-B