Configuration C: Thermostat Style - Nordson AD-31 Series Customer Product Manual

Extrusion handguns
Hide thumbs Also See for AD-31 Series:
Table of Contents

Advertisement

18
AD-31 Hand Guns
Ì Ì
Ì Ì
Figure 13 Connect the Electrical
Switch
Part 107105C04
Electrical Switch Connections (if applicable)
1. Find the orientation lug on the hose-cordset connector and ensure that
the connector and switch plug at the bottom of the handgun's handle are
properly aligned.
2. Attach the switch plug assembly at the bottom of the handle to the
connector on the hose cordset.
3. Refer to the melter manual to complete the hose installation to the
melter.
Configuration C: Thermostat Style AD-31
Connecting the Heater
Refer to Figure 14 as necessary.
Ground
Thermostat
Figure 14
Wiring Diagram
NOTE: The thermostatic sensor is factory prewired.
1. Loosen the two screws from the terminal block as shown in Figure15.
Insert wires 1 and 3, extending from the hose, into the terminal block.
Terminal
Block
L1, (Wire 1)
L2, (Wire 3)
Heater
E 2005 Nordson Corporation

Advertisement

Table of Contents
loading

This manual is also suitable for:

L4 series

Table of Contents