24
AD-31 Hand Guns
Startup
1
Figure 22
Lock Positions
1. Unlocked
Operation
Part 107105C04
CAUTION: Aggressive motion of the hose and handle can damage a
handgun with a microswitch, take care when swiveling the handgun.
WARNING: Risk of burns. Leave the trigger safety in the locked position to
prevent inadvertent discharge during startup until completing the startup
procedure.
1. See Figure 22. Make sure the trigger safety is locked.
2
2. Locked
2. Bring the adhesive to operating temperature, and then turn on the melter
pump.
NOTE: On standard models, the pump is continuously running. On models
with an electrical switch, the pump runs when the handgun is triggered.
3. Adjust the system hydraulic pressure to the required operating pressure.
1. Place the trigger lock in the unlocked position. See Figure 22.
2. Point the nozzle at the substrate.
3. Squeeze the handgun trigger to dispense adhesive.
4. Release the trigger to stop dispensing adhesive.
E 2005 Nordson Corporation