Shutdown

Maintenance

E 2005 Nordson Corporation
1. Place the trigger in the locked position. If necessary, see Figure 22.
2. Relieve system pressure. Refer to Safety.
3. Place the trigger lock in the unlocked position.
4. Place a waste container on the floor near the handgun's nozzle.
5. Drain adhesive from the handgun into the container until system
hydraulic pressure is relieved and the handgun is drained of adhesive.
Dispose of the drained adhesive.
6. Place the trigger in the locked position.
WARNING: Never hang the handgun by its trigger. Doing so can cause
accidental discharge, resulting in burns.
7. Hang the handgun by the hole at the top of the handle.
WARNING: Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation.
Preventive maintenance procedures for handguns consist of periodic
inspections, cleaning, and changing out adhesive.
CAUTION: Accumulated adhesive can char and cause erratic operation.
WARNING: Attempting any other maintenance procedure than those
described in this section can cause personal injury, handgun damage, or
improper system operation.
WARNING: Risk of death or serious injury from fire or toxic fumes.
Cleaning fluids other than Type R may present a toxic or fire hazard even at
room temperature.