The Open Wire accordion lists open wire diagnostics for all Cells configured in the Configuration file.
Cells that are not configured are displayed as a - (hyphen). Diagnostic data that is highlighted in
yellow indicates an open wire.
Figure 36. Open Wire accordion in Details Tab
To trigger diagnostics on all cells, click the "Acquire Open Wire Ratios" button. Once clicked, the open
wire scanning process begins.
Figure 37. Open Wire acquiring accordion in Details Tab
Once the open wire scanning has completed and all diagnostics data is collected it is displayed in a
tabular format with open wires highlighted in yellow.
Figure 38. Open Wire diagnostics accordion in Details Tab
The diagnostic values displayed are ratios of Voltage. Values very close to one ( > 0.97) indicate a
short condition. Values approaching zero (0.0 to 0.4) indicate an open wire connection.
Filtering
Use the filter to highlight ratios of Voltage that are above or below the specified value. The values
that match the criteria will be bolded and all other values will be faded.

5.3.2.7. SoC Calibration

Document ID: NE-DS-011