4.6
Probe - electrodes positioning
The burners are supplied with the combustion head and elec-
trodes.
NOTE:
In case of replacement of the electrodes, it is necessary to remove
the electrical panel.
Before installing the burner on the boiler, make sure
the probe and electrode are positioned correctly as
in Fig. 15. Use the screws 1) Fig. 14 to obtain the
correct distances.
WARNING
Do not turn the electrode: position it as illustrated.
Placing the electrode near the ionization probe may
result in the control box amplifier being damaged.
Fig. 14
20062175
Installation
20084009
22
GB
Electrode
Probe
20084010
Fig. 15