Attention: When sliding the retainer forward, make sure the two nubs on the retainer enter the
small holes on the M.2 backplane. Once they enter the holes, you will hear a soft "click" sound.
Figure 52. M.2 drive installation
After you install an M.2 drive in the M.2 backplane, complete the following steps:
1. Reinstall the M.2 backplane (see
backplane.html
).
2. Reinstall the compute node cover (see "http://thinksystem.lenovofiles.com/help/topic/7X21/install_the_
compute_node_cover.html" on page ).
3. Reinstall the compute node (see "http://thinksystem.lenovofiles.com/help/topic/7X21/install_a_
compute_node_in_the_chassis.html" on page ).
4. Check the power LED to make sure it transitions between fast blink and slow blink to indicate the node
is ready to be powered on.
5. Power on the node.
6. Exit maintenance mode.
7. Use the Lenovo XClarity Provisioning Manager to configure the RAID. For more information, see:
http://sysmgt.lenovofiles.com/help/topic/LXPM/RAID_setup.html
8. Verify that the M.2 module is replaced successfully:
• The amber warning light on the node front panel is off.
• The system boots successfully with no POST errors or other errors.
Adjust the retainer on the M.2 backplane
Use this information to adjust the position of the retainer on the M.2 backplane.
"Read the
installation
Guidelines" on
page 41
http://thinksystem.lenovofiles.com/help/topic/7X21/install_the_m2_
"Power off
the compute
node
for this task"
on page 32
"ATTENTION:
Static Sensitive Device
Ground package before opening"
on page 43
.
Chapter 8
Hardware replacement procedures
77