SETTING
For more information about the Twister Pro and its safety switch
functionalities, please refer to the Twister Pro Installation manual.
NOTE:
You have to program the safety switch both here in the mo-vis
Configurator and in the R-net Programmer.
Another parameter that you can set is the Debounce Timer. This will be
applied to all connected buttons except for the on/off button!
SETTING
Debounce
The input button has to be
timer
pressed for longer than the
Multi Joystick Installation Manual
DESCRIPTION
DESCRIPTION
PARAMETERS
Safety switch
Auto detect
50 mS
given.
You must connect a
safety switch. When
the safety switch fails,
a warning will be given.
You can connect a stan-
dard button or a safety
switch. When a safety
switch is connected
and it fails, a warning
will be given.
PARAMETERS
Min./Default