Symbols used Document ID This symbol on the front page of this instruction refers to the Docu- ment ID. By entering the Document ID on www.vega.com you will reach the document download. Information, note, tip: This symbol indicates helpful additional infor- mation and tips for successful work.
(e.g. lead, iron, concrete, etc.) provide effective shielding. Time: Stay as short a time as possible in radiation exposed areas. Distance: Your distance to the source should be as large as possible. The local dose rate of the radiation decreases in proportion to the square of the distance to the radiation source. VEGASOURCE 86 • Source holder...
We are at your disposal for further information concerning radiation protection and regulations in other countries. Appropriate use When in operating mode, the source container VEGASOURCE 86 described in this document contains a radiactive source for radio- metric level, interface and switching measurement as well as mass flow detection. The source container shields the radiation off from the...
We recommend changing the number combination to a personal number sequence. Make a note of the number combination and keep it in a safe place. Installation and operation in the USA and Canada This information is only valid for USA and Canada. Hence the follow- ing text is only available in the English language. VEGASOURCE 86 • Source holder...
That is why we have introduced an environment management system with the goal of continuously improving company environmental pro- tection. The environment management system is certified according to DIN EN ISO 14001. Please help us fulfil this obligation by observing the environmental instructions in this manual: • Chapter " Packaging, transport and storage" • Chapter " Disposal" VEGASOURCE 86 • Source holder...
• Serial number - Source • Loading date The serial number allows you to access the delivery data of the instru- ment via " www.vega.com", " Instrument search (serial number)". There are several versions available with different options for opening Versions or blocking the beam exit. Apart from the manual versions, there are also a version with pneumatic switching ON/OFF.
Page 10
Position of the type labels Fig. 2: Position of the type labels, e.g. version X, C - Manual switching ON/OFF Type label - Source holder Type label - Source Position indication " OFF" Position indication " ON" VEGASOURCE 86 • Source holder...
Page 11
Alternatively, you can access the data via your smartphone: • Download the VEGA Tools app from the " Apple App Store" or the " Google Play Store" • Scan the QR-code on the type label of the device or •...
The VEGASOURCE 86 is a source holder for shielding radioactive sources Co-60. The radioactive source in the source container emits gamma rays. The VEGASOURCE 86 is mounted on the vessel or the pipeline directly opposite the sensor. The source holder shields the environment against gamma radia- tion and protects the radioactive source from mechanical damage or chemical influences. In case of large measuring ranges (e.g. with high...
Check the hoisting equipment for sufficient lifting capacity. You can find the weight of the source holder in the " Technical data". Persons must never stand beneath the loads. When transporting, proceed according to the following illustrations. We recommend using a lift truck or a fork truck for transport to the place of use. VEGASOURCE 86 • Source holder...
Page 14
Please keep this mind while lifting the source holder out of the trans- port box. • Open the tension locks of the box lid with a large slotted screw- driver as shown in the illustration. • Remove the box lid and take loose accessories out of the box. • Open the tension locks on the side walls of the box with a large slotted screwdriver • Remove the side walls of the box down to the base plate • Guide the lifting bands through the ring eyelets on the side of the source holder VEGASOURCE 86 • Source holder...
Page 15
Unless otherwise indicated, the packages must be stored only under the following conditions: • Not in the open • Dry and dust free • Not exposed to corrosive media • Protected against solar radiation • Avoiding mechanical shock and vibration VEGASOURCE 86 • Source holder...
(ADR and DGR/IATA regulations). Accessories Protective cap To protect the switching mechanism of the VEGASOURCE 86 from dirt or contamination, a metallic protective cap is available. This also allows the padlock to be permanently protected from dirt, moisture and corrosion.
Page 17
Any number of devices can be synchronized. To synchronize several gamma modulators, you need a controller. Set of labels There is a special label set for the source holder which can be or- dered as a spare part. VEGASOURCE 86 • Source holder...
4 Mounting Mounting General instructions • General information For mounting of VEGASOURCE 86 you need a special handling permit. • Mounting may only be carried out by authorized, qualified person- nel who are monitored for radiation exposure according to local laws or the handling permit. Take note of the specifications in the handling permit. Also take the local conditions into account. • Carry out all work within the shortest possible time and at the larg- est possible distance.
To ensure a good electrical contact between the source holder and the mounting bracket, the lock washers must be used according to the following illustration. Use the prescribed torque for the mounting screws. Make sure that the screws have electrical contact to the potential equalization. VEGASOURCE 86 • Source holder...
Page 20
Lock washers (2 pieces) Cover (optional) To protect the switching mechanism of the VEGASOURCE 86 from dirt or contamination, a metallic protective cap is available. This also allows the padlock to be permanently protected from dirt, moisture and corrosion.
Page 21
"Radioactive". The responsible radiation safety officer can allow access after having checked the safety measures with switched-off source holder. If work must be carried out in and on the vessel, it is absolutely neces- sary to switch off the radiation on the source holder. VEGASOURCE 86 • Source holder...
Connect the ON/OFF position switches according to the following diagrams. Take note of the general installation regulations. As a rule, connect VEGASOURCE 86 to vessel ground (PA), or in case of plas- tic vessels, to the next ground potential. The data for power supply are specified in chapter " Technical data".
Page 23
ON/OFF position switch for switch position " OFF" (terminals 3 and 4) Switching amplifier For signal processing you need a NAMUR switching amplifier. We recommend the double channel switching amplifier VEGATOR 112. 5.1.2 Compressed air connection These instructions apply to source holders VEGASOURCE 86 Ver- sions B with pneumatic switching ON/OFF. Note: The pneumatic switching ON/OFF may only be put into operation after the source holder is mounted.
5 Installation - Special equipment Fig. 12: Connection of the pneumatic lines on VEGASOURCE 86 - version B 1 Ventilation filter/Sound absorber Voltage supply Voltage supply Terminal housing for connection of the ON/OFF position switches ON/OFF position switch for switch position " OFF" (terminals 3 and 4) ON/OFF position switch for switch position "...
Page 25
Connect the ON/OFF position switches according to the following diagrams. Take note of the general installation regulations. As a rule, connect VEGASOURCE 86 to vessel ground (PA), or in case of plas- tic vessels, to the next ground potential. The data for power supply are specified in chapter " Technical data".
(also not inside the vessel). Radiation must only be switched on by trained personnel. Switching the radiation The figures in brackets refer to the following illustration. Fig. 14: Switching the radiation on - VEGASOURCE 86 version X, C Loosen safety screw Fold up the safety screw Turn stirrup by 180°...
Page 27
Radiation "ON" ing status The marking arrow of the stirrup points to " ON". Fig. 15: Radiation " ON" - VEGASOURCE 86 Version X, C Radiation "OFF" The marking arrow of the stirrup points to " OFF". Fig. 16: Radiation " OFF" - VEGASOURCE 86 Version X, C Switching the radiation Switching off the radiation is analogous to this procedure. To switch...
6 Setup Fig. 17: Position indication with protective cap - VEGASOURCE 86 Version X, C Radiation " OFF" Radiation " ON" Version X With version X, the protective cap can be secured with a padlock in OFF position Version C...
Page 29
6 Setup Fig. 18: Indication of the switching status with VEGASOURCE 86 - Version B - Pneumatic switching ON/OFF Switching status " OFF" (symbol: closed padlock) Switching status " ON" (symbol: open padlock) • Remove padlock Note: The combination lock can be opened with the number combination 000 on delivery.
Page 30
6 Setup Analogue to this procedure, the radiation is switched off via the com- Switching the radiation pressed air controls. When the pneumatic switching ON/OFF is unpressurized, the VEGASOURCE 86 switches back automatically to switch position " OFF". VEGASOURCE 86 • Source holder...
If there are clear traces of corrosion on the source container, the local rosion dose rate (µSv/h resp. mR/h) must be measured in the surroundings. If the rate is clearly above the values during normal operation, then the area must be cordoned off and the responsible radiation safety officer informed. Corroded instruments and lock washers must be exchanged as soon as possible. VEGASOURCE 86 • Source holder...
Measure the local dose Measure the local dose rate of the source holder at regular intervals rate and document the measurement results. The measurement data allow conclusions to be drawn about leaks and possible changes in radiation power. VEGASOURCE 86 • Source holder...
In such case, the contamination test must be prescribed by the responsible radiation safety officer under consideration of the ap- plicable regulations and comprise, apart from the source holder itself, all other affected parts of the process vessel. VEGASOURCE 86 • Source holder...
Page 34
On source holders with pneumatic switching ON/OFF, the switch must be fixed with the lock in position " OFF" before starting the contamination test. 2. Have the samples analyzed by an authorized organisation. A radiation source is judged to be leaky if more than 185 Bq (5 nCi) are detected in the sample of the contamination test. VEGASOURCE 86 • Source holder...
24 hour service hotline For help with urgent technical problems, call the VEGA service hotline number +49 1805 858550. The hotline is manned 7 days a week round-the-clock. Since we offer this service worldwide, the support is only available in the English language.
Page 36
Informing the responsible Pass all necessary information immediately on to the responsible authority local and national authorities • After a thorough investigation of the situation on site, the respon- sible radiation safety officer must agree, together with the local authorities, on appropriate corrective measures for the existing problem Note: National regulations can prescribe deviating procedures and notifica- tion requirements. VEGASOURCE 86 • Source holder...
Also inform the relevant authority. If a return in your country is not possible, contact the respective sales partner to decide on further action. The destination airport for a possible return shipment is Frankfurt a. M., Germany. VEGASOURCE 86 • Source holder...
Page 38
The return shipment must be made in a type-tested type A pack- aging in accordance with the requirements of transport law rules (ADR/RID, IATA/DGR). The source holder VEGASOURCE 86 is suitable for return shipment. In case of doubt, your sales partner will provide you with suitable transport packaging.
Page 39
8 Dismount Before each shipment, check that the source holder still meets the specifications of a type A shipping package. VEGASOURCE 86 • Source holder...
9 Checklist type A packaging Checklist type A packaging Recurring test for return shipment Send the completely and correctly completed checklist to VEGA before return shipment. Requirements for personnel The personnel for diagnosis, maintenance and disassembly must meet the following requirements:...
Page 41
9 Checklist type A packaging Tests The completely and correctly completed checklist is available to VEGA before return shipment: Source holder If the above conditions are met, the source holder VEGASOURCE can be returned as type A packaging; howev- er, it must be relabelled.
651 mm (18.75") (25.63") 840 mm (33.06") Fig. 22: Source holder VEGASOURCE 86, version X, C - Manual switching ON/OFF Cover (optional) Free height for removal of the loading tube = 1320 mm (52 in) Features • Stirrup for manual switching ON/OFF •...
Page 47
10 Supplement VEGASOURCE 86, base plate 94 mm 289 mm 94 mm (3.69") (11.38") (3.69") Fig. 24: Base plate with holes (e.g. version X, C) VEGASOURCE 86 • Source holder...
Page 48
10 Supplement Gamma modulator (optional) ø 144 mm (5.67") 233 mm 160 mm (9.13") (6.30") Fig. 25: Gamma modulator for uninterrupted measurement even with X-ray radiation VEGASOURCE 86 • Source holder...
Les lignes de produits VEGA sont globalement protégées par des droits de propriété intellec- tuelle. Pour plus d'informations, on pourra se référer au site www.vega.com. VEGA lineas de productos están protegidas por los derechos en el campo de la propiedad indus- trial. Para mayor información revise la pagina web www.vega.com.
Need help?
Do you have a question about the VEGASOURCE 86 and is the answer not in the manual?
Questions and answers