Vents Breezy 160-E User Manual

Vents Breezy 160-E User Manual

Single room heat recovery ventilation unit

Advertisement

Quick Links

USER'S MANUAL
Breezy 160-E
Breezy 160-E-Smart
Single Room Heat Recovery Ventilation Unit
Breezy 200-E
Breezy 200-E-Smart

Advertisement

Table of Contents
loading

Summary of Contents for Vents Breezy 160-E

  • Page 1 USER’S MANUAL Breezy 160-E Breezy 200-E Breezy 160-E-Smart Breezy 200-E-Smart Single Room Heat Recovery Ventilation Unit...
  • Page 2: Table Of Contents

    Breezy 160-200-E (Smart) CONTENTS Safety requirements ..................................2 Purpose ........................................ 4 Delivery set ......................................4 Designation key ....................................4 Technical data ....................................5 Design and operating principle ............................6 Mounting and set-up .................................. 7 Connection to power mains ..............................9 Unit control .......................................
  • Page 3 Do not use the unit in a hazardous or explosive environment containing spirits, gasoline, insecticides, etc. Do not close or block the intake or extract vents in order to ensure the efficient air flow. Do not sit on the unit and do not put objects on it.
  • Page 4: Purpose

    Breezy 160-200-E (Smart) PURPOSE The ventilator is designed to ensure continuous mechanical air exchange in flats, cottages, hotels, cafés and other domestic and public premises. The ventilator is equipped with a regenerator that enables supply of fresh filtered air heated by means of extract air heat energy recovery.
  • Page 5: Technical Data

    Breezy 160-200-E (Smart) TECHNICAL DATA The temperature in the room where the indoor unit of the ventilator is installed must be in the range from +1 ˚C to +40 ˚C and relative humidity up to 70% (without humidity condensation). If the conditions for using the ventilator exceed the specified limits, switch off the ventilator.
  • Page 6: Design And Operating Principle

    Breezy 160-200-E (Smart) DESIGN AND OPERATING PRINCIPLE The unit consists of an air duct and a work module with an indoor unit. The work module contains fans, a heat exchanger, and heaters. The indoor unit is equipped with filters. The filters are designed to clean the air and prevent dust and foreign objects from entering the heat exchanger and the fan.
  • Page 7: Mounting And Set-Up

    300 min 300 2. Prepare a circular opening in the outside wall of the room with a minimum diameter of 162 mm for Breezy 160-E and min 300 206 mm for Breezy 200-E, sloping downwards towards the street.
  • Page 8 Breezy 160-200-E (Smart) 4. Install the air duct in the hole so that the end of the air duct is flush with the inside surface of the wall. The condensate drain (item 1) and the cut-out in the air duct (item 2) must face downwards.
  • Page 9: Connection To Power Mains

    Breezy 160-200-E (Smart) 8. Install the decorative panels. 9. Open the air intakes before switching on the system. If the air intake is not open and the product is running, it may damage the unit and cause it to malfunction. CONNECTION TO POWER MAINS The product is connected to a single-phase 230 V, 50 Hz AC mains supply by means of a power cable with a factory-fitted plug.
  • Page 10: Unit Control

    In the event of a software update, some descriptions in this manual may no longer be relevant. You can download the app by following the link to the App Store or Play Market, or by using QR codes. Vents Home – App Store Vents Home – Play Market...
  • Page 11 Breezy 160-200-E (Smart) Wi-Fi indicator on the front panel: Flashes rapidly Connection problems Setup Mode Flashes slowly is active Stays continuously lit Wi-Fi is connected to your home network Does not lit up Wi-Fi works in the access point mode or is turned off by the user via the mobile app The main modes, functions, settings available in the mobile application are as follows: On/Off The product can operate in passive ventilation mode when the air intakes are open and the motors are off.
  • Page 12 Breezy 160-200-E (Smart) Heat exchanger anti-icing protection This mode is used to prevent the product from icing up and involves activation of the condensate heater and the heater. The heat exchanger anti-icing protection activates automatically when the outdoor temperature drops to 0 °C and deactivates when the outdoor temperature rises to +2 °C.
  • Page 13 Breezy 160-200-E (Smart) Description of the system display Depending on the model, the product can be equipped with a display. The illustration below is an illustration of the screen layout. Indication on the display may differ depending on the system configuration. The display is configured using the mobile app. The digital segment of the display shows information such as time, temperature, humidity or all of them in sequence.
  • Page 14: Technical Maintenance

    Breezy 160-200-E (Smart) TECHNICAL MAINTENANCE DISCONNECT THE PRODUCT FROM THE POWER SUPPLY BEFORE PERFORMING ANY MAINTENANCE WORK Maintenance of the ventilator means regular cleaning of the ventilator surfaces of dust and cleaning and replacement of the filters. To access the filters, remove the decorative panels from the work unit. Remove the filters. Clean the filter as soon as it becomes dirty, but at least once every 3 months.
  • Page 15: Storage And Transportation Regulations

    Breezy 160-200-E (Smart) If necessary, the remote control battery may be replaced. No response of the unit for pressing the remote control buttons indicates the need to replace the battery. The battery type is CR2025. Remove the holder with the battery from the lower part of the remote control.
  • Page 16: Manufacturer's Warranty

    Breezy 160-200-E (Smart) MANUFACTURER’S WARRANTY The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby declare that the product complies with the provisions of Electromagnetic Compatibility (EMC) Directive 2014/30/EU of the European Parliament and of the Council, Low Voltage Directive (LVD) 2014/35/EU of the European Parliament and of the Council and CE-marking Council Directive 93/68/EEC.
  • Page 17 Breezy 160-200-E (Smart) www.ventilation-system.com...
  • Page 18 Breezy 160-200-E (Smart) www.ventilation-system.com...
  • Page 19: Certificate Of Acceptance

    Breezy 160-200-E (Smart) CERTIFICATE OF ACCEPTANCE Unit Type Single Room Heat Recovery Ventilation Unit Model Serial Number Manufacture Date Quality Inspector’s Stamp SELLER INFORMATION Seller Address Phone Number E-mail Purchase Date This is to certify acceptance of the complete unit delivery with the user’s manual. The warranty terms are acknowledged and accepted.
  • Page 20 V259EN-03...

This manual is also suitable for:

Breezy 160-e-smartBreezy 200-eBreezy 200-e-smart

Table of Contents