Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Vents Manuals
Fan
100 Quiet TP
User manual
Vents 100 Quiet TP User Manual
Axial fans
Hide thumbs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
page
of
24
Go
/
24
Contents
Table of Contents
Bookmarks
Advertisement
Table of Contents
1
Delivery Set
2
Brief Description
3
Maintenance
4
Transportation and Storage Rules
5
Manufacturer's Warranty
6
Indicator Light
7
Acceptance Certificate
Download this manual
model
AXIAL FANS
EN
VENTS Quiet
user's manual
www.ventilation-system.com
2013
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the 100 Quiet TP and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Vents 100 Quiet TP
Fan Vents 150 Quiet T User Manual
Axial fans (24 pages)
Fan Vents Quiet-S Manual
Axial fan (28 pages)
Fan Vents 100 Solid User Manual
Axial fan (16 pages)
Fan Vents 100 Style User Manual
Axial fan (20 pages)
Fan Vents 100 Quiet-dMEV DC User Manual
Axial fan (24 pages)
Fan Vents 100 User Manual
(20 pages)
Fan Vents VKP SERIES User Manual
Inline rectangular fans (28 pages)
Fan Vents VKO Series User Manual
Axial fan (24 pages)
Fan Vents VKO Series User Manual
Axial fan (28 pages)
Fan Vents D Series User Manual
Axial fan (24 pages)
Fan Vents Simple User Manual
Axial fan (20 pages)
Fan Vents 100 Base User Manual
Axial fan, base (24 pages)
Fan Vents 100 Base-I User Manual
Axial fan (24 pages)
Fan Vents Quiet 100 DC User Manual
Axial fan (24 pages)
Fan Vents FlexiVent 1060160/52x8 Installation Instructions Manual
(46 pages)
Fan Vents Quiet User Manual
Axial fans (32 pages)
Summarization of Contents
WARNING
DELIVERY SET
BRIEF DESCRIPTION
OPERATION GUIDELINES
MOUNTING
MAINTENANCE
TRANSPORTATION AND STORAGE RULES
MANUFACTURER'S WARRANTY
Fan Control Knob Adjustments
Turn-off Delay Knob T Adjustment
Adjusts the fan's delayed shutdown time from 2 to 30 minutes.
Humidity Set Point Knob H Adjustment
Sets the humidity threshold for fan operation from 60% to 90%.
OPERATION MODE SELECTION
Mode 1 (single-speed mode)
Fan operates at 1st speed when switch is closed or sensors activated.
Mode 2 (single-speed mode)
Fan operates at 2nd speed when switch is closed or sensors activated.
Mode 3 (two-speed mode)
Fan operates at 1st speed by default, switches to 2nd speed when activated.
Mode 4 (two-speed mode)
Fan starts at 1st speed, switches to 2nd speed with humidity sensor activation.
Mode 5 (two-speed mode)
Fan starts at 1st speed or humidity sensor activation, switches to 2nd speed.
OPERATING LOGIC (MODES 1-3)
Mode 1 Operation Logic
Logic for Mode 1, involving switch and turn-on/off delay timers.
Mode 2 Operation Logic
Logic for Mode 2, involving switch and turn-on/off delay timers.
Mode 3 Operation Logic
Logic for Mode 3, involving switch and turn-on/off delay timers.
TP MODEL OPERATION LOGIC (MODES 1-3)
TP Model Mode 1 Logic
Logic for TP model in Mode 1, involving motion detection and timers.
TP Model Mode 2 Logic
Logic for TP model in Mode 2, involving motion detection and timers.
TP Model Mode 3 Logic
Logic for TP model in Mode 3, involving motion detection and timers.
TH/VTH MODEL OPERATION LOGIC (MODE 1)
TH/VTH Model Mode 1 Logic
Logic for TH/VTH model in Mode 1, involving humidity and timers.
TH/VTH MODEL OPERATION LOGIC (MODE 2)
TH/VTH Model Mode 2 Logic
Logic for TH/VTH model in Mode 2, involving humidity and timers.
TH/VTH MODEL OPERATION LOGIC (MODE 3)
TH/VTH Model Mode 3 Logic
Logic for TH/VTH model in Mode 3, involving humidity and timers.
TH/VTH MODEL OPERATION LOGIC (MODE 4)
TH/VTH Model Mode 4 Logic
Logic for TH/VTH model in Mode 4, involving humidity and timers.
TH/VTH MODEL OPERATION LOGIC (MODE 5)
TH/VTH Model Mode 5 Logic
Logic for TH/VTH model in Mode 5, involving humidity and timers.
Detailed Control Adjustments and Operation Indication
Turn-on Delay Time Adjustment (Ton)
Adjusts the fan's delayed start time from 2 up to 30 minutes.
Turn-off Delay Time Adjustment (Toff)
Adjusts the fan's delayed shutdown time from 2 up to 30 minutes.
Humidity Set Point Adjustment (H)
Sets the humidity threshold for fan operation from 60% to 90%.
Indicator Light Status Interpretation
Explains the meaning of the indicator light colors and blinking patterns.
ACCEPTANCE CERTIFICATE
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the 100 Quiet TP and is the answer not in the manual?
Questions and answers