Appendix 1 Specifications
A-4
Downloaded from
Elcodis.com
electronic components distributor
• Without any Expansion Unit Installed
- NS15-V2/NS12-V1/-V2, NS10-V1/-V2, NS8-V1/-V2
Mounting angle of 0° to less than 30° to the horizontal:
Operating temperature range of 0 to 45°C
Mounting angle of 30° to 90° or less to the horizontal:
Operating temperature range of 0 to 50°C
- NS5-V1/-V2
Mounting angle of 0° to 90° or less to the horizontal:
Operating temperature range of 0 to 50°C
• With an Expansion Unit (Video Input Unit or Controller Link Unit) Installed
- NS15-V2/NS12-V1/-V2, NS10-V1/-V2
Mounting angle of 0° to less than 30° to the horizontal:
Operating temperature range of 0 to 35°C
Mounting angle of 30° to 90° or less to the horizontal:
Operating temperature range of 0 to 50°C
- NS8-V1/-V2
Mounting angle of 0° to less than 30° to the horizontal:
Operating temperature range of 0 to 35°C
Mounting angle of 30° to less than 90° to the horizontal:
Operating temperature range of 0 to 45°C
Mounting angle of 90° to the horizontal:
Operating temperature range of 0 to 50°C
2.
Operate the PT within the temperature and humidity ranges shown in the following dia-
gram.
90 °
Display surface
Humidity (RH)
Temperature (°C)
3. When a STN LCD display device is used, the display quality will decline (e.g., the contrast
ratio will be reduced) if the temperature exceeds 40°C. Also, when the temperature drops,
the response speed is lowered due to characteristics of liquid crystals.
This applies to the following models. Refer to NS-series PT Lot Numbers on page A-8 for
information on lot numbers.
Display device
Color STN LCD
Monochrome STN LCD
4. May not be applicable in locations with long-term exposure to oil.
30 °
Horizontal 0 °
Storage
Operating
PT model
NS5-SQ0@-V1
NS5-SQ@@-V2 with lot number earlier than 2110
NS5-MQ@@-V2

Advertisement