Majestic MER42N Installation Manual page 71

Hide thumbs Also See for MER42N:
Table of Contents

Advertisement

Good Faith TV Guidelines
WARNING! Risk of Fire!
opening is greater than 3 inches. Secure wire mesh to top of framing.
ROOM CEILING
MER36: 76 IN. MIN. (1930 mm)
MER42: 78 IN. MIN. (1981 mm)
(Appliance may be installed
off of floor)
83-1/2 IN. (2121 mm) MIN.
(Appliance may be
installed off of floor)
*
**
NOTE: The TV installation requirements are the same regardless of whether the Passive Heat kit is installed with a
Figure 10.17 Good Faith Guidelines for TV Installations Above a Fireplace with Passive Heat Option
Majestic • MER36N, MER36L, MER42N, MER42L Installation Manual • 2595-980 Rev. B • 5/23
Good Faith Guidelines for TV Installations
Above a Fireplace with Passive Heat Option
Wire mesh required on bottom of discharge opening when discharge
4 IN. MIN.
(102 mm)
41 IN. MIN. (1041 mm)
(MINIMUM CLEARANCE TO
DISCHARGE OPENING)
TV
12 IN. MIN.
(305 mm)
Measurement from top edge
of opening to bottom of
appliance = 33-1/2 IN. (851 mm)
Wire mesh required for front discharge or open top discharge passive heat installations with discharge
opening of three inches or greater.
For information on mantel requirements, refer to Section 2.B (Good Faith TV Guidelines for TV Installations)
and Section 10.C (Mantel and Wall Projections). If a fan is installed, a mantel is required to maintain the Good Faith
guidelines for TV installation. See Section 2.B and Section 2.C.
top discharge, side discharge or open top discharge.
1-1/2 IN. (2 X 4 FRAMING)
2 IN. MIN.
1/2 IN. X 1/2 IN.
WIRE MESH*
2 X 4 FRAMING
2 X 4 OR 2 X 6
FRAMING
**
CHASE CEILING REQUIRED
WITHIN 3 IN. (76 mm) OF TOP
OF OPENING
*
WIRE MESH
= PASSIVE HEAT
DISCHARGE OPENING
FIREPLACE
OPENING
71