Majestic MER36MN Installation Manual
Hide thumbs Also See for MER36MN:
Table of Contents

Advertisement

Quick Links

CAUTION! Risk of Fire! DO NOT store instruction manuals inside fireplace cavity.
High temperatures could cause a fire.
INSTALLER: Leave this manual with the appliance, not inside the appliance.
CONSUMER: Retain this manual for future reference. Do not store inside the appliance.
NOTICE: DO NOT discard this manual!
Models:
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
Installation Manual
Installation and Appliance Setup
Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and must be installed for
the protection of children and other at-risk
individuals.
Decorative barrier front must be ordered separately at
time of appliance purchase. See Section 3.B.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MER36MN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Majestic MER36MN

  • Page 1 Decorative barrier front must be ordered separately at appliance is not convertible for use with other time of appliance purchase. See Section 3.B. gases, unless a certified kit is used. Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 2: Table Of Contents

    B. Accessories ........76  = Contains updated information. Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 3: Installation Standard Work Checklist

    Comments: Further description of the issues, who is responsible (Installer/ Builder/ Other Trades, etc) and corrective action needed _____________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date)  = Contains updated information. 2599-982 1/23 Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 4: Product Specific And Important Safety Information

    State of California to cause cancer and reproductive harm. For more information go to: www. P65Warnings.ca.gov. Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 6: Getting Started

    Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualified service technician, service agency or your dealer. Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 7: Good Faith Wall Surface / Tv Guidelines

    °F 12 in. 6 in. MEASUREMENTS FROM TOP EDGE OF THE OPENING APPLIANCE FRONT Figure 2.2 Good Faith Wall Surface Temperatures Above Appliance With Passive Heat Kit Installed Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 8 Sugges�ons on how to further reduce TV temperatures: Increase “A” dimension. b. Increase “C” dimension, however, increasing “B” dimension beyond maximum recommended typically results in higher temperatures. Figure 2.3 Good Faith TV Guidelines Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 9 Increase “A” dimension. b. Increase “C” dimension, however, increasing “B” dimension beyond maximum recommended typically results in higher temperatures. Figure 2.4 Good Faith Guidelines - Passive Heat Kit Installed Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 10: Tools And Supplies Needed

    Technologies. • Improper positioning of the logs/media (as applicable) or the glass assembly. • Installation and/or use of any component part not approved by Hearth & Home Technologies. Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 11: Framing And Clearances

    45-3/16 1148 50-1/8 1273 5-3/16 2-1/16 8-5/16 26-11/16 41-13/16 1062 41-1/4 1048 6-3/8 35-3/8 35-1/2 1-1/8 17-11/16 42-7/8 1089 6-3/8 11-3/16 15-3/4 Figure 3.1 Appliance Dimensions (MER36MN, MER42MN) Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 12: Decorative Barrier Front Dimension Diagrams

    12 Inch Mantel Depth Top of Bottom (No Passive Heat) with Passive Heat Installed Surround 1-1/8 MER36MN MANOR36 1-1/8 MER42MN MANOR42 Figure 3.2 Decorative Barrier Front Dimensions - MANOR Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 13 Top of Bottom Mantel Depth with Passive Heat Installed Surround (No Passive Heat) 1-1/8 MER36MN ENSEMBLE36 1-1/8 MER42MN ENSEMBLE42 Figure 3.3 Decorative Barrier Front Dimensions - ENSEMBLE Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 14 Height at 12 Inch Mantel Depth Mantel Depth Top of Bottom (No Passive Heat) with Passive Heat Installed Surround 1-1/8 MER36MN ESSENCE36BK 1-1/8 MER42MN ESSENCE42BK Figure 3.4 Decorative Barrier Front Dimensions - ESSENCE Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 15 Top of Bottom Mantel Depth with Passive Heat Installed Surround (No Passive Heat) 1-1/8 MER36MN VENTURA36 1-1/8 MER42MN VENTURA42 Figure 3.5 Decorative Barrier Front Dimensions - VENTURA Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 16: Appliance Location And Clearances To Combustibles

    NOTICE: Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. Illustrations/diagrams are not drawn to scale. Actual installation may vary due to individual design preference. Figure 3.6 Clearance for Heat Management System Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 17 B = Front of surround to end of overhang C = Height of covered opening DIRECT VENT GAS FIREPLACE OUTDOOR FLOORING Figure 3.7 Protected Outdoor Applications - Dimensions Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 18 1067 1829 Mantel 55-7/8 Projections MER42MN 1419 1245 2007 17-3/4 For terminations MER36MN through a 2 x 4 wall, see Figure 19-3/4 MER42MN 3.9. Figure 3.8 Appliance Locations Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 19 BACK OF APPLIANCE TO FRONT OF DVP-TRAP1 WALL SHEATHING TERMINATION CAP INTERIOR SHEATHING 1/2 IN. THICK DVP90ST 5 IN. MIN Figure 3.9 DVP-TRAP1 Exception (2 x 4 Construction) Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 20 * Adjust framing dimensions for interior chase sheathing (such as sheetrock). C** Add 12 inches for rear venting with one 90 degree elbow. G*** For installations with vinyl flooring, see Section 3.E. Figure 3.10 Clearances to Combustibles Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 21 ** Measurement without Trim Kit = 2 in. + Additional Finishing Material Thickness. If finished discharge opening height is greater than 3 inches, wire mesh is required. Figure 3.11 Passive Heat Front Discharge Framing Dimensions With and Without a Trim Kit Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 22 Combustible Opening Opening Bottom of Appliance Bottom of Appliance Materials Inches 12-1/4 8-3/4 68-1/4 83-1/2 MER36MN MER42MN millimeters 1734 2121 Figure 3.12 Passive Heat Side Discharge Framing Dimensions Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 23 Mesh screen required for front discharge or open top discharge passive heat installations with discharge opening of 3 inches or greater. Figure 3.13 Passive Heat Minimum Framing Dimensions Open Top Discharge Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 24: Constructing The Appliance Chase

    Minimum height requirements for an exterior chase on a top- vented appliance are shown in Figure 3.14. Reference Fig- ure 4.5 for additional clearances. Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 25: Floor Protection

    FLOORING OR HEARTH MATERIAL ALLOWED UP TO TOP OF BOTTOM SURROUND See Detail A Front View Figure 3.16 Flooring & Hearth Material Allowed Figure 3.15 Vinyl Flooring Recommendations Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 26: Termination Location And Vent Information

    Over 20/12 to 21/12 ..........8.0 * H minimum may vary depending on regional snowfall. Refer to local codes. Figure 4.1 Minimum Height From Roof to Lowest Discharge Opening Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 27 V=Measure Vertical Distances from V Figure 4.3 OVERHANG WALL C and E dimensions are defined in Figure 4.5. Figure 4.4 Measure Horizontal and Vertical Termination Clearance to Trapezoid Portion of Cap Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 28: Vent Terminal Clearances

    42 in. (1067 mm) 42 in. (1067 mm) Figure 4.5 Minimum Clearances for Termination Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 29: Use Of Elbows

    4-1/4 DVP12 8-1/2 DVP24 DVP36 25-1/2 DVP48 1219 DVP6A 3 to 6 76 to 152 2-1/8-4-1/4 54-108 DVP12A 3 to 12 76 to 305 2-1/8-8-1/2 54-216 Figure 4.6 Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 30: Vent Diagrams

    Example: DVP pipe 3 ft. min. vertical = 11 ft. max. horizontal SLP pipe 7 ft. min. vertical = 11 ft. max. horizontal 1/4 in. max. (6 mm) Figure 4.8 Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 31 • Horizontal pipe installed level with no rise. MEASURE TO SHADED SURFACE (OUTSIDE MOUNTING SURFACE) Figure 4.9 Measure to Outside Mounting Surface Figure 4.10 Measure to Top of Last Section of Pipe Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 32 914 mm 11 ft. 3.4 m 4 ft. 1.2 m 20 ft. 6.1 m = 40 ft. (12.2 m) Maximum = 20 ft. (6.1 m) Maximum Figure 4.11 Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 33 = 1 ft. (305 mm) Minimum = 40 ft. (12.2 m) Maximum = 20 ft. (6.0 m) Maximum = 1 ft. (305 mm) Minimum INSTALLED HORIZONTALLY Figure 4.12 Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 34 914 mm 16 ft * 4.9 m* 3 ft. 914 mm 14 ft.* 4.3 m* = 20 ft. (6.1 m) Maximum = 40 ft. (12.2 m) Maximum Figure 4.13 Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 35 = 3 ft. Min. (914 mm) Note: If installing a vertical vent/ termination off the top of the ap- pliance, the flue restrictor should be used. Figure 4.14 Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 36 Note: If the DVP-2SL or DVP-SLP24 adapter is used with SLP pipe, you MUST subtract one number from Table 4.1. Example: Top vent 40 ft vertical with DVP pipe = 3-4 Top vent 40 ft vertical with SLP pipe = 2-3 Figure 4.16 Setting the Flue Restrictor Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 37 4 ft. 1.2 m 20 ft. 6.1 m = 50 ft. (15.2 m) Maximum *No specific restrictions on this value EXCEPT cannot exceed 50 ft (15.2 m) Figure 4.17 Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 38 4 ft. 1.2 m 18 ft. 5.5 m 18 ft. 5.5 m = 20 ft. (6.1 m) Maximum = 40 ft. (12.2 m) Maximum INSTALLED HORIZONTALLY Figure 4.18 Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 39: Vent Clearances And Framing

    Bottom: 1/2 in. (13 mm) Sides: 1 in. (25 mm) SCREW Figure 5.1 Horizontal Venting Clearances To Combustible Materials 3 in. (76 mm) Figure 5.2 Elbow Heat Shield Installation Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 40: Wall Penetration Framing/Firestops

    (1) in. (25 mm) above the center of the horizontal vent pipe. Note: Center of the horizontal vent pipe to the vertical measuring surface of a trap cap is 5 inches (127 mm). Figure 5.4 Wall Penetration Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 41: Ceiling Firestop/Floor Penetration Framing

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 5.6 Installing the Attic Shield Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 42: Appliance Preparation

    Figure 6.2 Cut Seal Cap Strap Using a Tin Snips and Bend the Pieces to 90 Degrees and Remove Seal Cap NOTICE: Once the seal cap has been removed it CANNOT be reattached. Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 43: Prepare For Heat Management

    Reference the appropriate instructions included with the kit for the remaining installation steps. PASSIVE HEAT ADAPTER KNOCKOUTS PASSIVE HEAT FRONT COVER KNOCKOUT Figure 6.4 Heat Management Knockout Locations Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 44: Securing And Leveling The Appliance

    FACTORY-INSTALLED NON-COMBUSTIBLE BOARD DO NOT REMOVE NAILING TABS (BOTH SIDES) Figure 6.7 Non-Combustible Board - Generic Decorative Barrier Figure 6.5 Proper Positioning and Securing of an Appliance Front Shown Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 45: Venting

    • Only outer pipes need to be sealed. All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed in this manner, unless otherwise stated. Figure 7.3 Figure 7.2 Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 46 • Only outer pipes need to be sealed. All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed in this manner, unless otherwise stated. Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 47: Assemble Slip Sections

    • Continue adding pipe as necessary following instructions in “Assembling Pipe Sections.” NOTICE: If slip section is too long, the inner and outer flues of the slip section can be cut to the desired length. Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 48: Secure The Vent Sections

    • SLP ceiling firestops have tabs that may be used to provide vertical support. 120º Figure 7.11 Align and Disassemble Vent Sections Figure 7.8 Securing Vertical Pipe Sections 120º Figure 7.9 Securing Horizontal Pipe Sections Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 49: Vertical Termination Requirements

    Slide the storm collar onto the exposed pipe section and align brackets. SEAL • Insert a bolt (provided) through the brackets and install nut. Do not completely tighten. Figure 7.14 Figure 7.14 Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 50: Horizontal Termination Requirements

    1-1/2 IN. (38 MM) MIN. HEAT SHIELD OVERLAP WALL SHIELD FIRESTOP SLIP SECTION CAN BE EXTENDED INNER VENT SHEATHING OUTER VENT INTERIOR EXTERIOR Figure 7.15 Venting Through the Wall Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 51: Electrical Information

    Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories. Figure 8.2 Junction Box Detail Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 52 To remove the IFT-ECM, gently pull up on the ECM, lifting it enough to clear the tabs (A) and disengage from tab B. Figure 8.3 Electrical Component Tray Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 53: Wiring Requirements

    (OPTIONAL) IFT-ACM MODULE IFT-WFM 2326-150 WIFI MODULE (OPTIONAL USB-C WIRE 6V DC HARNESS APPLIANCE BATTERY PACK ON/OFF 2326-222 CONTROL 2326-142 (OPTIONAL) Figure 8.4 IntelliFire Touch Wiring Diagram ® Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 54: Fan Installation

    • Reinstall valve plate assembly, burner assembly, base pan assembly, logs, appliance glass and decora- tive barrier front. FAN INSTALLED Figure 8.6 Fan Installed in Valve Plate Cavity Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 55: Gas Information

    1/2 in. (13 mm) control valve inlet. BOTTOM SURROUND • If substituting for these components, please consult local codes for compliance. Figure 9.1 Bottom Surround Removal (Generic Fireplace Shown) Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 56: High Altitude Installations

    • Tighten the wing nut. Air Shutter Settings (Factory Set to Minimum Vent Runs) MER42MN MODEL GAS TYPE MINIMUM VENT MER36MN 3/4 IN. MER42MN 3/4 IN. Figure 9.3 Burner Identification Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 57: Service/Replace Appliance Gas Valve

    VALVE PLATE ASSEMBLY FULL VALVE ACCESS TO REMOVE BOTTOM SURROUND: FLATTEN TABS PUSH BACK AND OUT TABS Figure 9.4 Gas Valve Access (Generic Fireplace Shown) Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 58: Finishing

    DECORATIVE BARRIER FRONT REQUIRED AIR FLOW GAP Flooring & Hearth Material (1-1/8 IN. MAX.) NO GAP ALLOWED Figure 10.1 Finishing Material Installed Figure 10.3 Required Air Flow Gap Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 59: Drywall Installation

    In addition to using multiple pieces of decorative finish material, the installation of the Passive Heat optional heat management system will also reduce the chances of cracking. Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 60: Installing A Television

    = 33-1/2 IN. (MER36MN) = 35-1/2 IN. (MER42MN) Note: Measurement is taken from top of the opening, Figure 10.4 Minimum Vertical and Maximum Horizontal Dimensions of Combustibles or Painted Surfaces Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 61 Figure 10.7 Minimum Vertical and Maximum Horizontal ∞ Millimeters Dimensions of Non-Combustibles - Passive Heat Kit Installed Figure 10.9 Non-Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening) Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 62 (DISCHARGE SLOTS ON BOTH SIDES OF APPLIANCE) 8-3/4 IN. (222 mm) REGISTER COVER SLOTS FACE FRONT OF APPLIANCE 12-1/4 IN. (311 mm) Figure 10.10 Finishing Material installed with Passive Heat Optional Heat Management System Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 63: Hearth Extension

    A table showing the fit option (Overlap or Inside) for each available decorative barrier front for this appliance is in- cluded for each finishing method (1.A, 1.B, 2.A). Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 64 Thick or Less - Overlap Fit Fronts NON-COMBUSTIBLE NON-COMBUSTIBLE FINISHING MATERIAL FINISHING MATERIAL Non-Combustible Finishing materials 6 inches maximum thickness. Stop finishing material flush with appliance opening. Figure 10.14 Inside Fit Method Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 65 ALIGNMENT DETAIL NON-COMBUSTIBLE NON-COMBUSTIBLE FINISHING MATERIAL FINISHING MATERIAL Figure 10.16 Install Finishing Strips DECORATIVE FRONT Figure 10.15 Non-Combustible Finishing Material Thickness Greater Than One Inch - Finishing Strips Required Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 66 NOTE: The TV installation requirements are the same regardless of whether the Passive Heat kit is installed with a top discharge, side discharge or open top discharge. Figure 10.17 Good Faith Guidelines for TV Installations Above a Fireplace with Passive Heat Option Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 67: Appliance Setup

    4. Install left and right side panels using same method. 5. Clean glass as instructed in appliance Owner’s manual. Figure 11.2 Glass Retainer in Position Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 68: Install Driftwood Logs (Optional)

    Figure 5. LOG PINS LOG PINS BURNER SCREW BURNER SCREW Figure 4 Place Log #1 Figure 5 Top View of Log #1 in Position Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 69 LOG PIN #12 LOG PIN #12 LOG PIN 5 LOG PIN 5 LOG PIN 7 LOG PIN 7 Figure 10 Place Log #5 Figure 11 Place Log #6 Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 70 Figure 15 8KMOD / MER42MN Shown - Base Pan Shown Painted Figure 14 6KMOD / MER36MN Shown - Base Pan Shown Unpainted Note Log #7 & # 8 Positions 2584-935 Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 71: Install Glass Media

    NOTICE: Excess media on burner and base pan may cause sooting. One thin layer of media may require less media than indicated in the Table 1. Figure 11.4 Media Bracket Location Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 72: Install Rock Jig For Optional Rock Media (Stones-Natural)

    If flames are dark orange with dark, smoky tips, provide more primary air to the burner by opening the air shutter accordingly. Figure 11.6 Place Rock Jig Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 73: Intellifire Touch ® Control System Setup

    1. The RC400 remote will need to be paired to the ECM. 2. Follow the installation instructions provided with the IntelliFire® Touch remote and/or accessory kit(s). Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 74: Fixed Glass Assembly Removal And Replacement

    • Inspect and operate all glass latches to ensure they move freely and no obstructions are present. • Reinstall decorative barrier front. LATCHES (BOTH BOTTOM GLASS FRAME AND TOP) TABS GLASS ASSEMBLY Figure 11.9 Fixed Glass Assembly Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 75: Reference Materials

    Decor Shroud 36 x 36 DTO146 Octagon Decor Cap LDS46 Decor Shroud 48 x 72 DTS134 Square Decor Cap LDS-BV Decor Shroud 26 x 26 DTS146 Square Decor Cap Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...
  • Page 76: Accessories

    Please contact your Majestic dealer with any questions or concerns. For the location of your nearest Majestic dealer, please visit www.majesticproducts.com. Printed in U.S.A. - Copyright 2023 Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23...

This manual is also suitable for:

Mer42mnMer36m series

Table of Contents