Majestic MER42N Installation Manual page 34

Hide thumbs Also See for MER42N:
Table of Contents

Advertisement

Top Vent - Horizontal Termination - (continued)
Two Elbows
WARNING! Risk of Fire! Elbow
heat shield required when V
ft. or less. Clearances to combus-
tibles must be maintained.
Section 5.A.
Note: For corner installations: A 6 in.
(152 mm) section of straight pipe may
need to be attached to the appliance
before a 90º elbow, to allow the vent
pipe to clear the top standoffs.
H
2
Figure 4.13
Majestic • MER36N, MER36L, MER42N, MER42L Installation Manual • 2595-980 Rev. B • 5/23
34
= 2
1
See
INSTALLED
HORIZONTALLY
V
Minimum
1
Elbow only
1/2 ft.
152 mm
1 ft.
305 mm
1-1/2 ft.
457 mm
2 ft.
610 mm
V
+ H
+ H
= 40 ft. (12.2 m) Maximum
1
1
2
H
+ H
= 25 ft. (7.6 m) Maximum
1
2
H
1
H
+ H
Maximum
1
2
2 ft
610 mm
6 ft.
1.8 m
11 ft.
3.4 m
18 ft.
5.5 m
25 ft.
7.6 m
V
1

Advertisement

Table of Contents
loading

Table of Contents