ELECTRICAL INFORMATION
Required Part: A Subpanel (230 volt Convertable) available from your
HOT SPRING dealer.
1. Disconnect the power cord from the house receptacle.
2. Open the equipment compartment door.
3. Remove the screws on the front of the spa control box.
4. Open the control box cover.
5. Identify Terminal block located in the lower left-hand corner inside the
control box.
6. Refer to illustration, Step 1.
Remove the 2 pin jumper
attached to terminals
4 and 5.
7. Refer to illustration, Step 1.
Remove the wire jumper from
terminals 2, and 6.
8. Refer to illustration, Step
2. Remove the power cord
wires from 5, 7 and GRD (not
illustrated).
9. Unscrew the power cord strain
relief and remove the power
cord from the access hole in
the control box.
WARNING: Do not allow
pliers to contact any electronic
components inside the control
box.
IMPORTANT! The exact physical location of the terminals on the GFCI
breaker will vary between manufacturers. Connecting the hot wire to the neutral
terminal will cause irreversible damage to the control box.
** Refer to NEC 250-122 (table)
NOTE: The wire connections to GFCI breakers are for reference only. Always ensure the white neutral wire is connected to the load neutral of the 20 amp breaker.
*AVAILABLE FROM DEALER.
Step 1
Remove the Terminal Block Power Jumper
using needlenose pliers From terminal 4-5.
Remove wire jumper from 2 & 6.
Remove the three power cord wires from
Step 2
terminal block 5,7 and GRD. Leave Terminal
Block Power Jumper 6-7 in place.
JETSETTER & BEAM I
230 volt converted model
Converting from 115 volts to 230 volts changes the voltage supplied
to the heater from 115-volts to 230 volts. The jet pump will continue to
operate at 115 volts.
Have your licensed electrician wire subpanel from a 50A Main Service, then
from subpanel into the spa's control box using the following illustration or
use the wire diagram on the inside of the control box lid.
The subpanel must be placed in sight of the spa, at a
IMPORTANT:
minimum distance of 5 feet away.

WIRING CONNECTIONS

IMPORTANT: Fill the spa with water before turning on the power
• Once your spa has been filled with water, turn it on and test all the
circuit breakers.
Each breaker should be tested prior to each use. Here's how:
1. Push the "TEST" button on each GFCI breaker, and observe it click
off.
2. Wait 30 seconds, then push the breaker switch to the OFF (down)
position (to ensure that it has completely disengaged), then push the
breaker switch to the ON (up) position. If you don't wait 30 seconds,
the spa's power indicator may continue to blink – try again.
If any of the GFCI breakers fails to operate in this manner, your spa may
have an electrical malfunction, and you may be risking electrical shock.
Turn off all circuits and do not use the spa until the problem has been
corrected by an authorized service agent.
IMPORTANT: Service Technician must reconfigure spa using the soft
jumpers to allow spa heater to run concurrent with jet pump.
IMPORTANT: ALL WIRING SHOULD BE COPPER.