Cold Water Connection; Connecting The Hot Water Boiler - STIEBEL ELTRON MEK-K Manual

Non-pressurised tap for oversink water heater
Hide thumbs Also See for MEK-K:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

INSTALLATION
Installation
6.1

Cold water connection

f Seal the thread of the butterfly valve using hemp or Teflon
tape.
f Fit the butterfly valve, together with pipe collar and flat gas-
ket, to the cold water pipe.
f Seal the thread of the tap body using hemp or Teflon tape.
Only wall mounted cylinders above 30 l
f Screw the tap extension together with flat gasket to the tap
body.
f Seal the thread of the tap extension using hemp or Teflon
tape
All DHW cylinders
f Fit the tap body (with a tap extension if necessary), together
with a flat gasket, to the butterfly valve. Align the tap body
horizontally when doing so.
20
| MEK-K | MED-D
6.2

Connecting the hot water boiler

3
2
1 Cold water connection
2 Connection to tap body
3 DHW connection
f If necessary shorten the connection pipes to the required
length and deburr the cut edges.
f Loosen the union nuts of the compression fittings at the con-
nections on the tap body.
f Insert the connection pipes vertically through the union nuts
into the connections on the tap body.
f Screw the connection pipes loosely to the tap body using the
union nuts.
f Fit the hot water boiler.