Download Print this page

Advertisement

Quick Links

Intel® Storage System SSR316MJ2
Specification Update
May 2005
The Intel® SSR316MJ2 Storage System SSR316MJ2 may contain design defects
or errors known as errata which may cause the product to deviate from published
specifications. Current characterized errata are documented in this Specification
Update.
Order Number: C78132-005

Advertisement

loading
Need help?

Need help?

Do you have a question about the SSR316MJ2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Intel SSR316MJ2

  • Page 1 Intel® Storage System SSR316MJ2 Specification Update May 2005 The Intel® SSR316MJ2 Storage System SSR316MJ2 may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are documented in this Specification Update.
  • Page 2 Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel’s Terms and Conditions of Sale for such products, Intel...
  • Page 3: Table Of Contents

    Contents Revision History....................5 Preface......................... 7 Summary Table of Changes................9 Errata ......................... 12 Specification Changes ..................15 Specification Clarifications ................16 Documentation Changes.................. 17 Intel® Storage System SSR316MJ2 Specification Update...
  • Page 4 This page intentionally left blank. Intel® SSR316MJ2 Storage System SSR316MJ2 Specification Update...
  • Page 5: Revision History

    Revision Description November 2004 Initial release for Production SSR316MJ2 . December 2004 December 2004 release for Production SSR316MJ2 . March 2005 March 2004 release for Production SSR316MJ2 May 2005 May 2005 release for Production SSR316MJ2 Intel® SSR316MJ2 Storage System SSR316MJ2 Specification Update...
  • Page 6 Preface This page intentionally left blank. Intel® SSR316MJ2 Storage System SSR316MJ2 Specification Update...
  • Page 7: Preface

    C75916-001 Nomenclature Errata are design defects or errors. These may cause the Intel® Storage System SSR316MJ2 behavior to deviate from published specifications. Hardware and software designed to be used with any given stepping must assume that all errata documented for that stepping are present on all devices.
  • Page 8 SATA HBA (Drive Interface Cards) 713L FIRMWARE C41625-005, C41625-006 Power Supply Fab #’s SAN Management Software initial 6.0.25.0014 release SAN Management Software Update 1 6.0.25.0017 SAN Management Software Update 2 6.0.25.0018 SAN Management Software Update 3 60.25.0021 Intel® SSR316MJ2 Storage System SSR316MJ2 Specification Update...
  • Page 9: Summary Table Of Changes

    The following table indicates the Errata, Specification Changes, Specification Clarifications, or Documentation Changes that apply to the Intel® Storage System SSR316MJ2. Intel may fix some of the errata in a future stepping of the component, and account for the other outstanding issues through documentation or specification changes as noted.
  • Page 10 Removing a drive in RAID 0 does not show alerts SSC hangs when changing power supply status monitored variables Fixed Nofix SSC install and EBSD host driver install fails on Microsoft* Windows* Server 2003 with Service Pack 1 Intel® SSR316MJ2 Storage System SSR316MJ2 Specification Update...
  • Page 11 Specification Clarifications Page Status SPECIFICATION CLARIFICATIONS None for this revision of this specification update. Documentation Changes Page Status DOCUMENTATION CHANGES Back Panel I/O Ports and Features diagram incorrect. EMC & Safety Information was omiited. Intel® Storage System SSR316MJ2 Specification Update...
  • Page 12: Errata

    Building RAID 5/50 arrays takes significantly longer to complete with BBU verses Implication: without BBU. Complete RAID 5/50 array builds without BBU attached. Workaround: Fix. Will be fixed in a future release of the product. Status: Intel® SSR316MJ2 Storage System SSR316MJ2 Specification Update...
  • Page 13 There is no known workaround at this time. However, for fault tolerance, RAID 0 Workaround: implementations with the Intel® Storage System SSR316MJ2 product should only be used in clustered environments with volume replication. Fix. Will be fixed in a future release of the product Status: Intel®...
  • Page 14 NOTE: In a Production environment or with a server exposed to the Internet, it is recommened that this setting be restored immediately after the Java based installation program is complete. Nofix. There are no plans to fix this erratum. Status: Intel® SSR316MJ2 Storage System SSR316MJ2 Specification Update...
  • Page 15: Specification Changes

    Errata Specification Changes None for this revision of this specification update. Intel® Storage System SSR316MJ2 Specification Update...
  • Page 16: Specification Clarifications

    Documentation Changes Specification Clarifications None for this revision of this specification update. Intel® SSR316MJ2 Storage System SSR316MJ2 Specification Update...
  • Page 17: Documentation Changes

    Status: Hardware Technical Product Specification. EMC & Safety Information was omiited Critical product EMC & Safety information was omitted from the 1.0 revision of the Intel® Storage System SSR316MJ2 Problem: Hardware Technical Product Specification, as listed below: Electromagnetic Compatibility Notices FCC Verification Statement (USA) 1.1.1...
  • Page 18 This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the interference-causing equipment standard entitled “Digital Apparatus,” ICES-003 of the Canadian Department of Communications. Intel® SSR316MJ2 Storage System SSR316MJ2 Specification Update...
  • Page 19 Install and use the equipment according to the instruction manual. BSMI (Taiwan) 1.5.1 The BSMI Certification Marking and EMC warning is located on the outside rear area of the product. (Korea) 1.6.1 Intel® Storage System SSR316MJ2 Specification Update...
  • Page 20 5. Manufacturer/Nation: Intel Corporation/Refer to country of origin marked on product Safety Cautions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Resource CD and/or at http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
  • Page 21 Consider wearing protective gloves. Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warn- und Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-Serverplatinen und - Servergehäusen auf der Ressourcen-CD oder unter http://support.intel.com/support/motherboards/server/sb/cs- 010770.htm.
  • Page 22 Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le CD Resource CD ou bien rendez-vous sur le site http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
  • Page 23 Documentation Changes Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el CD Resource y/o en http://support.intel.com/support/motherboards/server/sb/cs-010770.htm. INSTRUCCIONES DE SEGURIDAD: Cuando extraiga la tapa del chasis para acceder al interior del sistema, siga las siguientes instrucciones: Apague todos los dispositivos periféricos conectados al sistema.
  • Page 24 Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio. È consigliabile l'uso di guanti di protezione. All users of Intel® Storage System SSR316MJ2 should be familiar with the above safety guidleines to ensure proper safety Implication: practices before operating or servicing this equipment.