Table of Contents

Advertisement

Quick Links

Operating and
Service Manual
1200A225B
Model
10053654
Part Number
Serial Number
160 Schoolhouse Road, Souderton, PA 18964 • 215-723-8181 • Fax 866-859-0582 • www.arworld.us

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1200A225B and is the answer not in the manual?

Questions and answers

Summary of Contents for AR 1200A225B

  • Page 1 Operating and Service Manual 1200A225B Model 10053654 Part Number Serial Number 160 Schoolhouse Road, Souderton, PA 18964 • 215-723-8181 • Fax 866-859-0582 • www.arworld.us...
  • Page 3 REGULATION (EC) 1907/2006 of the European Parliament and of the Council of 18 December 2006 concerning the Registration, Evaluation, Authorization and Restriction of Substances of Very High Concern Chemicals (SVHC) Supporting documentation is held by AR RF/Microwave Instrumentation’s Quality department in Pennsylvania, United States. Place of issue:...
  • Page 5 Instructions for European EMC Conformity WARNING It is the responsibility of the user of this equipment to provide electromagnetic shielding, filtering and isolation which is necessary for EMC compliance to Directive 2014/30/EU. The equipment must therefore be operated in a shielded area which provides a sufficient level of attenuation to meet the radiated emissions and immunity specifications.
  • Page 7 The caution symbol denotes a potential hazard. Attention must be given to the statement to prevent Your AR equipment may have more than one power supply cable. Use damage, destruction, or harm. only approved power cable(s). If you have not been provided with a Dangerous voltages are present.
  • Page 8 EQUIPMENT CONTAINING LASERS risk of serious injury due to unsafe AR Field Probes (FL/PL Series) and Field Analyzers (FA product handling should be a fundamental Series) are Class 1 laser products containing embedded consideration every user.
  • Page 9 Zur Vermeidung von Personen- oder Sachschäden gilt BEVOR SIE DAS GERÄT ANSCHLIESSEN es, die Hinweise zu beachten. Ihre AR-Ausrüstung hat möglicherweise mehr als ein Stromversorgungskabel. Gefährliche elektrische Spannungen sind vorhanden. Verwenden Sie nur zugelassene Stromkabel. Falls Sie kein Stromkabel oder Höchste Vorsicht ist geboten.
  • Page 10 Die meisten Geräte müssen während des Versands, der Montage und des Gebrauchs LASER-INFORMATION transportiert werden. Jeder Nutzer sollte sich AR - Feldsonden (FL/PL-Serie) und Feldanalysatoren (FA-Serie) über das Risiko von schweren Verletzungen sind Laserprodukte der Klasse 1 mit eingebetteten Klasse-4- durch unsachgemäße...
  • Page 11 électrode de mise à la Votre équipement AR peut disposer de plus d’un câble d’alimentation terre de protection. électrique. Utilisez uniquement un ou des câbles d’alimentation approuves.
  • Page 12 éliminer le risque injustifié de blessures causées par le levage est fournie par les méthodes de travail de NIOSH (publication Les sondes de champ AR (série FL/PL) et les analyseurs de n° 94-110) disponibles sur : champ (série FA) sont des produits laser de classe 1 contenant des lasers intégrés de classe 4.
  • Page 13 Er zijn gevaarlijke elektrische spanningen aanwezig. Wees uiterst voorzichtig. VOOR HET OPZETTEN VAN DE STROOM Uw AR-apparatuur kan meer dan een netvoedingskabel bezitten. Gebruik alleen goedgekeurde netvoedingskabel(s). Koopt een Wijst op een terminal aan die bedoeld is voor aansluiting netvoedingskabel die is goedgekeurd voor gebruik in uw land als u...
  • Page 14 APPARAAT DAT LASERS BEVAT distributie, de assemblage en het gebruik moeten worden behandeld, moet het risico AR-terreinsondes (FL/PL-serie) en terreinanalysatoren (FA- op ernstig letsel als gevolg van een serie) zijn laserproducten van klasse 1 met ingesloten onveilige behandeling van het product een klasse 4-lasers.
  • Page 15: Table Of Contents

    TABLE OF CONTENTS TABLE OF CONTENTS ....................i GENERAL INFORMATION ................1 General Description ....................1 Specifications ......................1 Installation ......................1 1.3.1 Location ........................1 1.3.2 Primary Power ......................2 OPERATING INSTRUCTIONS ................ 5 General ........................5 Amplifier Front and Rear Panels ................6 Interface Identification ...................
  • Page 16 Model 1200A225B 2.7.1 Power OFF, RF OFF .................... 22 2.7.2 Power ON, RF OFF ....................22 2.7.3 Power ON, RF ON ....................22 Control Lines ......................23 2.8.1 Switch Breakout Board (A14A3) ................. 23 2.8.1.1 Connector J9 ....................23 2.8.1.2 Connector J8 ....................
  • Page 17 Model 1200A225B 3.2.4 A7 Four-Way Combiner ..................42 3.2.5 A8 Bi-Directional Coupler ................... 42 3.2.6 A9 Detector ......................42 Power Supplies ..................... 42 Control System ..................... 43 3.4.1 A14 Control/Fault Board ..................43 3.4.2 A15 Interface Board ..................... 43 3.4.3 A16 ALC ......................
  • Page 18 Typical Response at -20dBm Input ..............50 Typical A1 Pre-Amplifier Response -20 dBm Input ..........51 Typical A1 Pre-Amplifier Response 0 dBm Input ..........51 1200A225B Right Side, Modules A3-A5 ............52 Connectors ......................52 SMA Module Input ....................53 Final Module RF Output ..................
  • Page 19: General Information

    Select an operating location that will permit air to circulate freely around the amplifier’s cabinet. The Model 1200A225B utilizes air cooling and should be located where the normal flow of air into or exiting from the unit will not be restricted, diverted, or re-circulated through the unit itself; in particular, the flow of warm air exiting the rear of the amplifier should not be impeded.
  • Page 20 Model 1200A225B 1.3.2 Primary Power The Model 1200A225B is designed to operate using AC primary power of 200–240 Volts Alternating Current (VAC), 50–60 Hz single phase, 4000 watts maximum. CAUTION: Dangerous voltages are present in the Model 1200A225B whenever the unit is plugged into an AC outlet.
  • Page 21 Amplifiers Model 1200A225B The Model 1200A225B is a solid-state, This is a high-power Class A amplifier. Class A design, self-contained, air- The low level of spurious signals and cooled, broadband power amplifier linearity make it ideal for EMC Test Features:...
  • Page 22 Model 1200A225B • 1200 W • .01 - 225 MHz Electrical Specifications Parameter Symbol Minimum Typical Maximum Unit Rated Power Output (.01 – 100 MHz) PSAT 1200 1350 >1400 Rated Power Output (100 – 225 MHz) PSAT 1100 1250 >1300 Input for Rated Output Power Output @ 3 dB Compression (.01 –...
  • Page 23 Model 1200A225B • 1200 W • .01 - 225 MHz Mechanical Specifications Parameters Unit 50.3 x 47 x 65.3 Dimensions (With Cabinet) (W x H x D) 19.8 x 18.5 x 25.7 48.3 x 44.5 x 65.3 Dimensions (No Cabinet) – 10U for 19” Rack 19.0 x 17.5 x 25.7...
  • Page 24 Connector Enclosure RF Sample Ports Front Enclosure Front Rear No Enclosure Rear Contact your AR RF/Microwave Instrumentation Sales Associate for specific model configuration pricing. Envelope Drawing AR RF/Microwave Instrumentation • 160 Schoolhouse Rd, Souderton, PA 18964 • 215-723-8181 • info@arworld.us •...
  • Page 25 Model 1200A225B • 1200 W • .01 - 225 MHz TYPICAL PSAT POWER @ 0dBm INPUT, 1 dBm, 3dBm 2000 1800 1600 1400 1200 1000 Freq. (MHz) P1dB P3dB P@0dBm Input TYPICAL SMALL SIGNAL GAIN @ -20dBm INPUT Freq. (MHz) AR RF/Microwave Instrumentation •...
  • Page 26: Primary Power

    Model 1200A225B • 1200 W • .01 - 225 MHz TYPICAL 2 HARMONICS @ 1000 W Freq. (MHz) AR RF/Microwave Instrumentation • 160 Schoolhouse Rd, Souderton, PA 18964 • 215-723-8181 • info@arworld.us • www.arworld.us • ISO 9001:2015 Certified • ISO 17025:2017 Accredited...
  • Page 27 Freq. (MHz) AR RF/Microwave Instrumentation • 160 Schoolhouse Rd, Souderton, PA 18964 To order AR Products, call: 215.723.8181. For an applications engineer, call: 800.933.8181. Direct to Service call: 215.723.0275 or email: service@arworld.us For Faxing Orders: 866.859.0582 (Orders Only Please) info@arworld.us Approved for public release by AR RF/Microwave Instrumentation ISO 9001:2015 Certified •...
  • Page 29: Operating Instructions

    2. OPERATING INSTRUCTIONS GENERAL Operation of the Model 1200A225B broadband amplifier is quite simple. The amplifier’s input signal, whether swept or fixed in frequency, is fed into the jack marked RF INPUT, and the amplifier’s output signal is taken from the jack labeled RF OUTPUT. The unit is turned on by activating the front panel POWER switch. In the event of a major malfunction, protection is provided by a circuit breaker located on the unit’s rear panel.
  • Page 30: Amplifier Front And Rear Panels

    Model 1200A225B AMPLIFIER FRONT AND REAR PANELS Figure 2-1 shows the front panel of the Model 1200A225B broadband amplifier. Figure 2-2 shows the rear panel of the Model 1200A225B broadband amplifier. Figure 2-1. Model 1200A225B Front View Item Title Function INHIBIT, LOCAL, REMOTE Keylock Switch, 3-position;...
  • Page 31: Interface Identification

    Model 1200A225B INTERFACE IDENTIFICATION This section describes all external interfaces used to operate the amplifier via the control software. A LOCAL/REMOTE switch on the front panel can allow control from the Local Controls or Remote Communications Ports. 2.3.1 Local Controls The control panel located on the front of the amplifier allows for local control and status monitoring using the controls listed below.
  • Page 32: Inputs And Outputs

    Model 1200A225B INPUTS AND OUTPUTS The input and output connectors described in the following sections are located on the unit’s front or rear panels; refer to the Front and Rear Panel features drawings (Figure 2-1, Figure 2-2). 2.4.1 RF Input This Type N connector is the RF input to the amplifier.
  • Page 33 Model 1200A225B 2.4.2.1.1 Center Conductor Inspection Index Description New Condition Normal Use-Slight gap Bent pin section-Discard connector Fingers spread or collapsed-Discard connector Broken pin or pin section-Discard connector 2.4.2.1.2 Center Pin Concentricity Index Description Centered Maximum allowable off-center Fall-off center-Discard connector 2.4.2.1.3...
  • Page 34: Mating 7-16 Din Connectors

    Model 1200A225B 2.4.2.1.4 Cleaning Procedure 1. Remove loose particles on the mating surfaces, threads, and similar surfaces using low-pressure compressed air. Avoid forcing dirt down into the connector by applying the forced air at a slight angle. 2. Use only isopropyl alcohol 90% for cleaning the connector parts. Clean the threads of the connector with a narrow-tipped lint-free cotton swab dampened with isopropyl alcohol 90%.
  • Page 35: Mating Of 7-16 Din Connectors

    Model 1200A225B Figure 2-5. Placement of Wrenches on Connector 2.4.2.4 De-Mating of 7-16 DIN Connectors De-mating of the 7-16 connectors can be achieved by utilizing a similar technique as described in the mating portion of this application note. To de-mate the 7-16 interface, place one wrench on the body of the connector, and a second wrench on the connecting nut of the attached device or adapter.
  • Page 36: Ieee-488, Usb, And Rs-232 Interfaces

    2.4.3 IEEE-488, USB, and RS-232 Interfaces The Model 1200A225B’s remote interfaces allow remote control, via a computer, of all amplifier functions (except for the Keylock Switch position) that can be controlled from the front panel. When the amplifier is in the Remote mode (as determined by the position of the Keylock Switch), a special Remote display is shown.
  • Page 37: Local User Interface

    Model 1200A225B LOCAL USER INTERFACE This section describes the user interface used during local operation of the amplifier as it pertains to the control system. 2.6.1 Menu Map Below is a menu map for the amplifier. The screens depicted are only example screens. The values and settings will be different on the actual amplifier depending on user settings and operating conditions.
  • Page 38: Main Menu Screen

    Model 1200A225B 2.6.3 Main Menu Screen The Main Menu screen is only available when the Keylock switch is in the LOCAL position. At the top of the screen is a blue bar graph and associated number that can represent either the RF Gain, ALC Threshold, ALC Detector Gain, or ALC Response value.
  • Page 39: Select Screen

    Model 1200A225B 2.6.4 Select Screen The Select screen is the same as the Main Menu screen except for the menu options. The menu options in this screen allow the user to select what parameter the ADJUST knob can adjust. Once a selection is made, the screen will automatically change back to the Main Menu screen.
  • Page 40: User Screen

    Model 1200A225B 2.6.6 User Screen The User screen presents the user with the revision levels of all the firmware that is running on all the main control system components. For the Switch Breakout Board (SBB) assemblies, the piggy-back assembly firmware is listed. At the bottom of the screen, the RF On and Power On Operating Hours are displayed. A menu option is provided for accessing the settings for the remote I/O ports found on the rear of the unit (see I/O Screen section) and for setting the VSWR Limit (see VSWR Limit section).
  • Page 41: Vswr Limit Screen

    Model 1200A225B 2.6.8 VSWR Limit Screen The VSWR Limit screen is used to set a software limit on the calculated output VSWR. If the calculated output VSWR exceeds the selected limit, a fault will be triggered, and the RF Output will be disabled.
  • Page 42: Gpib Address Screen

    Model 1200A225B 2.6.10 GPIB Address Screen The GPIB address screen is used to select the GPIB address. To get here from the Main Menu, touch the User menu button followed by the I/O menu button and finally the GPIB menu button.
  • Page 43: Key Beep Screen

    Model 1200A225B 2.6.12 Key Beep Screen The Key Beep screen allows the user to turn on or off the audible beep that occurs when a valid touch event takes place. This setting is only stored in volatile memory and will be lost when power to the unit is cycled.
  • Page 44: Fault Screen

    Model 1200A225B 2.6.14 Fault Screen The Fault screen will appear anytime that a fault condition is met. The name of the fault is shown toward the center of the screen. In either LOCAL or REMOTE Keylock switch positions, a Reset button will appear allowing local resetting of the fault condition.
  • Page 45: Control States

    Model 1200A225B Remotely, the ALC Lockout state affects the Level Adjust and the Mode Select commands. In the locked state, the Level Adjust command for ALC Threshold, Detector Gain, and Response Time are simply ignored. This is also true of the Mode Selection. These commands can be issued to the amplifier while in the locked state, but their associated values will not change regardless of the Keylock position.
  • Page 46: Power Off, Rf Off

    Model 1200A225B 2.7.1 Power OFF, RF OFF AC power is applied, the Keylock in not INHIBIT. The control system is waiting for a user action or a remote command. 2.7.2 Power ON, RF OFF The Power button has been pressed or the remote command for ‘Power On’ has been sent.
  • Page 47: Control Lines

    Model 1200A225B CONTROL LINES This section defines all required control lines to be utilized by the control software and any actions (faults or alerts) that the control software must perform. In the tables below, indicate the NO ACTION STATES (or the correct operating states) of each line required and any actions that are required if the line is out of bounds.
  • Page 48: Connector J5

    Model 1200A225B 2.8.1.3 Connector J5 Lines 3, 4: Supplies +3.3 Vdc via a 10kOhm pull-up resistor Lines 1-4: Guaranteed operation up to +30 Vdc Lines 3, 4: 0 Vdc or +3.3 Vdc TTL Inputs & OD Outputs: Guaranteed operation up to +5 Vdc...
  • Page 49: Fault Definition

    Model 1200A225B FAULT DEFINITION This section is used to define all faults that can occur and their source. Use the Control Line column to define what active control line generates the fault or use the text Internal for an internally generated fault from the control system (i.e ‘Internal 485 bus error’).
  • Page 50: No-Fault Control Actions

    Model 1200A225B 2.9.1 No-Fault Control Actions This section describes all no-fault actions taken by the controls system and their sources. Use the Control Line column to define what active control line generates the fault or use the text Internal for an internally generated fault from the control system (i.e ‘Internal 485 bus error’).
  • Page 51: 2.10 Remote Control Interfaces

    Model 1200A225B 2.10 REMOTE CONTROL INTERFACES This section describes remote operation of the amplifier using the provided General Purpose Interface Bus (GPIB), RS-232 serial port, fiber-optic serial ports, Universal Serial Bus (USB), and Ethernet port. All ports are always active, however only one port may be used at a time.
  • Page 52: Fiber-Optic Serial Communications

    Core Size: 50um (minimum) to 200um (recommended) Connector Type: This port can be used in conjunction with a serial to fiber-optic or USB to fiber-optic interface, such as an AR IF7001 USB to Fiber-Optic interface. *NOTE: The IF7001 device uses SMA connectors, so a fiber-optic cable is needed with ST connectors on one end and SMA connectors on the other.
  • Page 53: Ethernet Communications

    Once installed, the DeviceInstaller™ utility will scan the network and find all connected Lantronix Ethernet devices. This list of found devices will include any connected AR Ethernet devices. By selecting one of the connected devices from the list, its IP address and subnet mask can be changed along, with several other settings.
  • Page 54: Power On / Off

    Model 1200A225B 2.11.1 Power On / Off This command controls the power state. No other command will be accepted until the POWER:ON command has been issued. It is good practice to wait a minimum of two (2) seconds before polling the status after issuing the POWER:ON command.
  • Page 55: Power Indicator Frequency

    Model 1200A225B 2.11.5 Power Indicator Frequency This command sets the current frequency used to correct the forward and reverse power indicators shown on the display. The correction factors used by this feature are set from the factory and stored in non-volatile memory.
  • Page 56: Alc Mode

    Model 1200A225B 2.11.7 ALC Mode This command sets the mode of the Automatic Leveling Control (ALC) feature to either a default mode (MANUAL) or a user-configurable mode (ALC INT). In the default mode (MANUAL), the ALC Detector Gain, ALC Response, and ALC Threshold settings do not affect the operation of the ALC feature because factory settings are used instead.
  • Page 57: Alc Response Setting Adjust

    Model 1200A225B 2.11.10 ALC Response Setting Adjust This command sets the ALC response setting. Adjusting this setting changes the ALC’s response time when reacting to a detected increase in the RF Output that exceeds the ALC Threshold Level. LEVEL:RESP<resp setting>...
  • Page 58: Machine State Query

    Model 1200A225B 2.11.13 Machine State Query This command queries the RF gain, detector gain, ALC threshold, and ALC response time. MSB? Query: RF<space>GAIN=<rf_gain>,DT<space>GAIN=<det_gain>,THRES=<alc_thresh>, Response Format: RESP=<resp><LF> <rf_gain>: The RF Gain setting (0-100%), padded with leading spaces to be 3 characters The ALC Detector Gain (0-100%), padded with leading spaces to be 3 characters <det_gain>:...
  • Page 59: Amplifier State Query

    Model 1200A225B 2.11.14 Amplifier State Query This command queries the state of the amplifier. STATE? Query: STATE=<space><char1><char2><char3><char4><LF> Response Format: <char1> - <char4>: ASCII character (0 to 9 or A to F) representing a hexadecimal character To query the state of the amplifier, send the following command: Example: STATE?<LF>...
  • Page 60: Hex Character To Binary Bits Conversion Table

    Model 1200A225B 2.11.14.1 Hex Character to Binary Bits conversion table Below is a table that can be used as a reference when deciphering the response from the STATE query. The binary bits of each of the four ASCII characters from the response can be located here.
  • Page 61: Reverse Power Query

    Model 1200A225B 2.11.16 Reverse Power Query This command queries the internally detected reverse power (values are corrected and linearized).. RPOW? Query: RPOW=<power><LF> Response Format: The detected reverse power (0-99999) in Watts (value is always five <power>: characters, padded with spaces).
  • Page 62: Reset Faults

    Model 1200A225B 2.11.20 Reset Faults This command clears a resettable fault. A fault can only be cleared if the underlying issue that created the fault has been resolved. RESET Syntax: None Parameters: Example To clear a reported fault, send the following command: RESET<LF>...
  • Page 63: Clear Fault Log

    Model 1200A225B 2.11.23 Clear Fault Log Use this command to clear the entire contents of the error log. This action is permanent and cannot be undone. FSTA:LOG:CLEAR Syntax: None Response Format: To clear the entire fault log, send the following command: Example: FSTA:LOG:CLEAR<LF>...
  • Page 64: Sbb (Piggyback) Firmware Query

    Model 1200A225B 2.11.26 SBB (Piggyback) Firmware Query This command queries the firmware of the piggyback SBB assembly. *SBB? Query: SBB_SW_REV<revision><LF> Response Format: Where: x is the firmware revision. <revision>: The revision of the SBB assembly. To query the piggyback SBB firmware revision, send the following...
  • Page 65: Theory Of Operation

    3. THEORY OF OPERATION INTRODUCTION The Model 1200A225B RF amplifier consists of a .01-225 MHz RF amplifier assembly. The RF amplifier assembly consists of a pre-amplifier/driver module, and a four-way splitter that drives (4) final amplifier modules. These 4 final amplifier modules are combined through (1) four-way combiner to yield a combined power of 1200 watts or more.
  • Page 66: A7 Four-Way Combiner

    POWER SUPPLIES The Model 1200A225B contains five switching power supplies. The input voltage range to the power supply is 200–240 VAC, 50/60Hz. The AC input power is approximately 4000 watts. PS1 is a multiple output power supply. PS1 has a +5V, standby supply for the A14 control panel, the A15 remote interface board used for the remote interfaces, the -15V supplied to the A1 preamp and the A3 through A6 final modules.
  • Page 67: Control System

    Model 1200A225B CONTROL SYSTEM 3.4.1 A14 Control/Fault Board The A14 Control/Fault board consists of one 16-bit microcontrollers and several other ICs that monitor and indicate the status of the amplifier. Power is supplied using only a single 5-volt power supply. The board offers...
  • Page 68 Model 1200A225B Rev A...
  • Page 69: Maintenance

    Section 4.3. Shipping instructions are as follows. To return an item, contact AR Customer Service for an RMA number and shipping instructions. Returns from outside the United States are not permitted without prior authorization. If shipping from outside of the United States, closely follow all directions on the RMA form for return shipping and marking.
  • Page 70: Troubleshooting

    LDMOS and other ESD-sensitive devices. Troubleshooting the Model 1200A225B in a logical manner can speed the solution to a problem. The settings of potentiometers (pots), capacitors (caps), or other variables should not be disturbed until other problems have been eliminated.
  • Page 71: General - Reading Faults

    RF energy when these doors are opened. NOTE: The Model 1200A225B is shipped with a mating connector, which has a jumper between Pins 1 and 8, installed in the rear panel interlock connector. The unit will not operate unless the interlock circuit is closed.
  • Page 72: Interlock Fault

    Model 1200A225B 4.3.4.1 Interlock Fault 1. In the event of an Interlock Fault, the front panel display should read INTERLOCK. 2. Check to see if it is safe to be power up the unit—are there personnel present in the screen room, or are doors to the screen room open? 3.
  • Page 73: Alc Fault

    Low or No Power Output (DC Tests) (Schematic 10048583, 10050414) All indicators on the Model 1200A225B are normal, the front panel display reads RF On, and the cooling fans are operating. 1. Check the position of the RF Gain control—is it set to maximum gain? 2.
  • Page 74: Low Or No Power Output (Rf Test)

    1. The Model 1200A225B’s typical gain response at 0 dBm input and -20 dBm input is shown in Figures 4-1 and 4-2. The actual gain may vary considerably from that shown in Figure 4-1 but should be ≥ 60.8 dBm.
  • Page 75 Model 1200A225B 2. The typical response for the A1 Pre-Amplifier/Driver (at maximum gain setting) is shown in Figures 4-3 and 4-4. Figure 4-3. Typical A1 Pre-Amplifier/Driver Response -20dBm Input NOTE: The A1 Pre-Amplifier’s response may differ considerably—particularly in flatness—from the typical responses shown in the Figure 4-4.
  • Page 76: Locating And Replacing Modules

    LOCATING AND REPLACING MODULES Remove enclosure and side panels to gain access to Final modules. See Figure 4-5. Figure 4-5. 1200A225B, Right Side, Modules A3-A5. Disconnect the green connector, the SMA input and output connectors. See Figures 4-6 through 4-9.
  • Page 77: Sma Module Input

    Model 1200A225B Figure 4-7. SMA Module Input Figure 4-8. Final Module RF Output Rev A...
  • Page 78: Rf Module

    Model 1200A225B Figure 4-9. RF Module Remove the four mounting screws holding the module in place. Install new replacement module using a new thermal pad (P/N 10051176). Tighten the four mounting screws in an X pattern to ensure even pressure.
  • Page 79: Appendix A. Installing Software Upgrades

    Appendix A. Installing Software Upgrades The 1200A225B has the capability to upgrade software. The first step that should be taken is to power-down the unit from the front panel. 1. Go to the AR Website and download the AR Firmware Upgrade Utility along with the model specific upgrade file for the device being upgraded.
  • Page 80 Model 1200A225B Rev A...
  • Page 81 These modules are not field-repairable and should never be opened outside of AR’s Microelectronics Lab. The modules in these product lines have a security label on two sides of the modules between the housing and lid/cover. If the security label is removed and or cut, the warranty of the module will be voided.