Riello RLS 68/E MX Installation, Use And Maintenance Instructions page 79

Dual fuel light oil / gas burners
Table of Contents

Advertisement

Wiring layout key
+BB
Burner components
+BC
Boiler components
A1
Control box for the air/fuel ratio
A2
Operator panel
B
Filter to protect against radio disturbance
B1
Output regulator RWF50
B2
Fuel meter
BA
Input in current DC 4...20 mA
BA1
Input in current DC 4...20 mA to modify remote set-
point
BP
Pressure probe
BP1
Pressure probe
BR
Remote setpoint potentiometer
BT1
Thermocouple probe
BT2
Probe Pt100, 2 wires
BT3
Probe Pt100, 3 wires
BT4
Probe Pt100, 3 wires
BTEXT
External probe for climatic compensation of the set-
point
BV
Input in voltage DC 0...10V
BV1
Input in voltage DC 0...10V to modify remote setpoint
F1
Fan motor thermal relay
F2
Pump motor thermal relay
FU1
Three-phase power supply fuses
H
Remote lockout signal
h1
Operation hour counter
IN
Burner manual stop switch
K1
Relay "K1" (clean contacts "FLAME ALIGHT")
K2
Relay "K2" (clean contacts "BURNER LOCK-OUT")
K3
Relay "K3" (clean contacts "OVERLOAD" fan motor)
KG
Gas operation "KG" relay
KMP
Pump motor contact maker
KMV
Fan motor contact maker
KO
Light oil operation "KO" relay
MP
Pump motor
MV
Fan motor
OCI
Communication interface for Modbus system
PA
Air pressure switch
PE
Burner earth
PGM
Maximum gas pressure switch
PGMin
Minimum gas pressure switch
PGVP
Gas pressure switch for valve leak detection control
device
POilMin
Minimum oil pressure switch
POilMax
Maximum oil pressure switch
Q1
Three-phase line disconnecting switch
Q2
Single-phase line disconnecting switch
QRA
Flame sensor
RS
Remote burner reset button
S1
On/off selector
S5
Fuel selector
SM1
Air servomotor
SM2
Gas servomotor
Appendix - Electrical panel layout
TA
TL
TR
TS
VFOil
VROil
VR1Oil
VSOil
X1
X4
X6
X7
XP1
XP4
XP6
XP7
XPD
XPGM
XPGMin
XPGVP
XPOilMax Maximum oil pressure switch connector
XPOilMin
Y
77
GB
Ignition transformer
Limit thermostat/pressure switch
Adjustment thermostat/pressure switch
Safety thermostat/pressure switch
Light oil working valve
Light oil adjustment valve
Light oil adjustment valve
Oil safety valve
Burner terminal strip
4-pin plug
6-pin plug
7-pin plug
Connector for output power regulator kit RWF50
4-pole socket
6-pole socket
7-pole socket
Operator panel connector
Maximum gas pressure switch connector
Minimum gas pressure switch connector
Gas pressure switch connector for gas leak control
Minimum oil pressure switch connector
Gas regulator valve + gas safety valve
20121288

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rls 120/e mx779t1780t1

Table of Contents