Once you have confirmed, the sign "–" will appear.
Continue in the same way for the other characters.
After inserting the last character of the password, confirm by
pressing the key "i/reset": if the password inserted is correct you
will see "PArA" for a few seconds, then you can access the var-
ious groups of parameters.
With the keys "+" and "–" select the group you require.
P
/reset
P
If the password inserted is incorrect, the message "Error" will
appear for a moment. It is then necessary to repeat the proce-
dure.
P
The password must only be communicated to the
qualified personnel or the Technical Assistance
Service, and must be kept in a safe place.
WARNING
WARNING
Once the access procedure has been carried out, the display will
show "PArA" for a few seconds.
P
Select the desired group of parameters with keys "+" and "-",
and confirm by pressing the key "i/reset".
Within the group you have chosen, scroll through the list with the
keys "+" and "-". At the end of the list, the display shows "End".
To return to Normal visualisation mode, simultaneously press the
keys "+" and "-" (ESC) twice.
20121288
Start-up, calibration and operation of the burner
V
h min
s
%
V
h
min
s
%
V
h min s
%
V
h min
s
%
ESC
/reset
6.8.4.2 Assigning parameter levels
The parameters level is subdivided into groups as shown in Tab.
R.
No.
Parameter
100: ParA
General parameters
Information and identification data of the system.
200: ParA
Burner checks (Fuel 0)
Type of operation, intervention and safety times
of the various phases.
300: ParA
Burner checks (Fuel 1)
Type of operation, intervention and safety times of
the various phases.
400: Set
Air/fuel modulation curve
Setting of air/fuel adjustment points
500: ParA
Positioning of servomotors
Choice of positions of the air/fuel servomotors in
the various phases.
600: ParA
Servomotors
Setting and addressing of the servomotors.
700: HISt
Log of the errors
Choice of different visualisation modes for the er-
rors log.
900: dAtA
Process information
Visualisation of information for the remote man-
agement of the burner.
All the parameters are checked in the factory.
Modification/tampering may compromise the
good operation of the burner and cause injury to
people or damage to things. In any case, modifi-
WARNING
WARNING
cations must be carried out by qualified person-
nel.
To modify a parameter, refer to paragraph "Parameter modifi-