Sign In
Upload
Manuals
Brands
Riello Manuals
Burner
RLS 68/E
Riello RLS 68/E Manuals
Manuals and User Guides for Riello RLS 68/E. We have
2
Riello RLS 68/E manuals available for free PDF download: Installation, Use And Maintenance Instructions
Riello RLS 68/E Installation, Use And Maintenance Instructions (48 pages)
Dual fuel light oil/gas burner
Brand:
Riello
| Category:
Burner
| Size: 6.44 MB
Table of Contents
Table of Contents
3
Information and General Instructions
5
Information about the Instruction Manual
5
Introduction
5
General Dangers
5
Other Symbols
5
Delivery of the System and the Instruction Manual
6
Guarantee and Responsibility
6
Safety and Prevention
7
Introduction
7
Personnel Training
7
Technical Description of the Burner
8
Technical Data
8
Electrical Data
8
Burner Models Designation
9
Packaging - Weight - Approximate Measurements
9
Burner Dimensions
10
Firing Rates
10
Procedure to Refer Burner Operating Condition at an Altitude And/Or at a Combustion Supporter Air Temperature Different to the Standard Values (328 Ft above Sea Level, 68 °F)
11
Minimum Furnace Dimensions
12
Standard Equipment
12
Burner Description
13
Control Box for the Air/Fuel Ratio (LMV36
14
Actuators (SQM33.5
17
Installation
18
Notes on Safety for the Installation
18
Handling
18
Preliminary Checks
18
Burner Raising
19
Preparing the Boiler
19
Boring the Boiler Plate
19
Blast Tube Length
19
Securing the Burner to the Boiler
20
Electrode Position
20
Ignition Pilot Adjustment
20
Nozzle
21
Recommended Nozzles
21
Nozzle Assembly
21
Adjusting the Nozzle Flow Rate
22
Combustion Head Setting
23
Burner Refitting
23
Light Oil Supply
24
Hydraulic Connections
25
Pump
25
Pump Priming
25
Gas Feeding
26
Gas Train
26
Gas Pressure
27
Electrical Wiring
28
Supply Cables and External Connections Passage
29
Thermal Relay Calibration
30
Electro-Mechanical Thermal Relay
30
Electronic Thermal Relay
30
Motor Connection at 208-230 or 460V
31
Motor Connection at 575V
31
Reversible Direction
31
Start-Up, Calibration and Operation of the Burner
32
Notes on Safety for the First Start-Up
32
Adjustments before First Firing (Light Oil Operation)
32
Combustion Head Setting
32
Pump Adjustment
32
Air Damper Adjustment
32
Burner Firing
32
Adjustments before First Firing (Gas Operation)
32
Burner Start-Up
33
Adjusting Gas/Air Delivery
33
Adjusting Oil/Air Delivery
33
Final Calibration of the Pressure Switches
34
Air Pressure Switch
34
Maximum Gas Pressure Switch
34
Minimum Gas Pressure Switch
35
Low Oil Pressure Switch
35
High Oil Pressure Switch
35
Burner Starting (Fuel Oil Adjustment)
36
Steady State Operation
36
Firing Failure
36
Flame Signal Measurement
37
Final Checks (with the Burner Working)
37
Maintenance
38
Notes on Safety for the Maintenance
38
Maintenance Programme
38
Maintenance Frequency
38
Safety Test - with Gas Ball Valve Closed
38
Checking and Cleaning
38
Safety Components
39
Opening the Burner
41
Closing the Burner
41
Faults - Possible Causes - Solutions
42
A Appendix - Spare Parts
43
B Appendix - Accessories
46
Appendix - Burner Start up Report
47
Advertisement
Riello RLS 68/E Installation, Use And Maintenance Instructions (48 pages)
Dual fuel light oil/gas burners, Progressive two-stage or modulating operation
Brand:
Riello
| Category:
Burner
| Size: 2.57 MB
Table of Contents
Table of Contents
3
1 Information and General Instructions
5
Information about the Instruction Manual
5
Introduction
5
General Dangers
5
Safety Precautions
5
Danger: Live Components
5
Guarantee and Responsibility
6
Owner's Responsibility
6
2 Safety and Prevention
7
Introduction
7
Personnel Training
7
3 Technical Description of the Burner
8
Technical Data
8
Burner Models Designation
8
Electrical Data
9
Three Phase Burner
9
Three Phase Burner
10
Burner Description
11
Packaging - Weight - Approximate Measurements
12
Burner Dimensions
12
Standard Equipment
12
Firing Rate
13
Procedure to Refer Burner Operating Condition in High Altitude Plants
13
Minimum Furnace Dimensions
15
Control Box for the Air/Fuel Ratio (LMV36
16
Actuators (SQM33.5
19
4 Installation
20
Notes on Safety for the Installation
20
Handling
20
Preliminary Checks
20
Boiler Plate
20
Burner Raising
21
Blast Tube Length
21
Securing the Burner to the Boiler
21
Nozzle
22
Recommended Nozzles
22
Nozzle Assembly
22
Adjusting the Nozzle Flow Rate
23
Electrode Position
24
Burner Refitting
24
Hydraulic System
25
Fuel Supply
25
Hydraulic Connections
26
Pump
26
Pump Priming
26
Gas Line
27
Gas Train
27
Gas Pressure
28
Electrical Wiring
29
Thermal Relay Calibration
30
Electro-Mechanical Thermal Relay
30
Electronic Thermal Relay
30
Motor Connection at 208-230 or 460V
31
Motor Connection at 575V
31
Reversible Direction
31
5 Start-Up, Calibration and Operation of the Burner
32
Notes on Safety for the First Start-Up
32
Adjustments before First Firing (Light Oil Operation)
32
Combustion Head Setting
32
Pump Adjustment
32
Air Damper Adjustment
32
Ignition Pilot Adjustment
32
Adjustments before First Firing (Gas Operation)
33
Burner Start-Up
34
Adjusting Gas/Air Delivery
34
Adjusting Oil/Air Delivery
34
Final Calibration of the Pressure Switches
35
Air Pressure Switch
35
Maximum Gas Pressure Switch
35
Minimum Gas Pressure Switch
36
Low Oil Pressure Switch
36
High Oil Pressure Switch
36
Burner Starting
37
Steady State Operation
37
Firing Failure
37
Flame Signal Measurement
38
Final Checks (with the Burner Working)
38
6 Maintenance
39
Notes on Safety for the Maintenance
39
Opening the Burner
40
To Open the Burner
40
To Close the Burner
40
A Appendix - Spare Parts
41
B Appendix - Accessories
45
Appendix - Burner Start up Report
46
Advertisement
Related Products
Riello RLS 68/EVi MX FS1
Riello Bio RLS 68/M
Riello Bio RLS 68/MX
Riello RLS 68/E MX
Riello RLS 650/E
Riello RLS 650/M MX
Riello RLS 610/E MX
Riello RLS 650/E MX
Riello RLS 610/M MX
Riello RLS 610/EV O2 MX
Riello Categories
Burner
Boiler
Indoor Fireplace
UPS
Water Heater
More Riello Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL