Riello RLS 68/E MX Installation, Use And Maintenance Instructions page 52

Dual fuel light oil / gas burners
Table of Contents

Advertisement

Parameter
No.
Description
Burner operation mode (fuel supply line, modulating/
stage, servomotors, etc.)
-- = not defined (eliminate curves)
1 = Gmod
2 = Gp1 mod
3 = Gp2 mod
4 = Lo mod
5 = Lo 2 stage
6 = Lo 3 stage
7 = Gmod pneu
8 = Gp1 mod pneu
9 = Gp2 mod pneu
301
10 = LoGp mod
11 = LoGp 2-stage
12 = Lo mod 2 fuel valves
13 = LoGp mod 2 fuel valves
14 = G mod pneu without actuator
15 = Gp1 mod pneu without actuator
16 = Gp2 mod pneu without actuator
17 = Lo 2-stage without actuator
18 = Lo 3-stage without actuator
19 = G mod only gas actuator
20 = Gp1 mod only gas actuator
21 = Gp2 mod only gas actuator
22 = Lo mod only oil actuator
(Fuel 1) Gas: selection of flame sensor
321
0 = QRB.../ QRC
1 = ION / QRA
(Fuel 1) Gas: Selection of the pre-purging function
322
0 = deactivated
1 = activated
Maximum repeats of minimum gas pressure switch
intervention
323
1 = No repetition
2...15 = Number of repetitions
16 = Constant repetitions
325
(Fuel 1) Gas: pre-purging time
326
(Fuel 1) Gas: Spark pre-ignition time
330
(Fuel 1) Gas: interval 1
332
(Fuel 1) Gas: interval 2
333
(Fuel 1) Gas: post-combustion time
(Fuel 1) Gas: Post-purging time (no extraneous light
334
test)
(Fuel 1) Gas: Minimum gas pressure switch input
0 = deactivated
1 = minimum gas pressure switch (upstream of the
336
fuel valve 1 (V1))
2 = valve control via the minimum pressure switch
(between fuel vale 1 (V1) and 2 (V2))
(Fuel 1) Gas: Maximum gas pressure switch / POC
Input
0 = deactivated
337
1 = Maximum gas pressure switch
2 = POC
3 = Leak detection control pressure switch
(Fuel 1) Gas: Valve leak detection test
0 = test deactivated
1 = valve leak detection test at start up
341
2 = valve leak detection test at shutdown
3 = valve leak detection test at start-up and at shut-
down
(Fuel 1) Gas: Post-purging time (t3)(at deactivation of
348
the load (LR)) - ON
(Fuel 1) Oil: selection of flame sensor
361
0 = QRB.../ QRC...
1 = ION / QRA...
365
(Fuel 1) Oil: pre-purging time
366
(Fuel 1) Oil: Spark pre-ignition time
370
(Fuel 1) Oil: interval 1
372
(Fuel 1) Oil: interval 2
373
(Fuel 1) Oil: post-combustion time
20121288
Start-up, calibration and operation of the burner
No. of
measure-
elements
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Unit of
Values interval
Modifica-
tion
Min.
ment
Modify/set to
-
1
zero
-
Modification
0
-
Modification
0
-
Modification
1
s
Modification
20s
s
Modification
0.4 s
s
Modification
0.4 s
s
Modification
0.4 s
s
Modification
0.2s
s
Modification
0.2s
-
Modification
1
-
Modification
1
-
Modification
0
s
Modification
1s
-
Modification
0
s
Modification
15s
s
Modification
0.6s
s
Modification
0.4 s
s
Modification
0.4 s
s
Modification
0.2s
50
GB
Degree of
Predefined
precision
setting
Max.
22
1
Not defined
1
1
1
1
1
1
16
1
16
60 min
0.2s
20s
60 min
0.2s
2s
60s
0.2s
2s
60s
0.2s
2s
60s
0.2s
8s
108 min
0.2s
0.2s
2
1
1
2
1
1
3
1
2
108 min
0.2s
1s
1
1
0
60 min
0.2s
15s
60 min
0.2s
2s
60 min
0.2s
2s
60 min
0.2s
2s
60s
0.2s
8s
Access mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode