Copy Of Safety Label For U39E Gas Stove; Decal Location - Regency Ultimate U39E-NG12 Owners & Installation Manual

Freestanding gas stove
Table of Contents

Advertisement

This is a copy of the label that accompanies each ULTIMATE Direct Vent
Freestanding Gas Stove. We have printed a copy of the contents here for your
review. The safety label is located on the inside of the drop down pedestal door.

Copy of Safety Label for U39E Gas Stove

Listed: VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION
Certifi ed to/Certifi é :
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
Refer to Intertek's Directory of Building Products for detailed information.
Pour plus de détails, se reporter au Répertoire des produits de construction de Intertek.
C# 4001172
FACTORY EQUIPPED FOR NATURAL GAS:
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Model U39E-NG12: Factory Equipped for Altitude 0-2000 ft.
Orifi ce size
Altitude
Maximum Input
Minimum Input
Model U39E-NG12: Convertible for Altitude 0-4500 ft.
Orifi ce size
Altitude
Maximum Input
Minimum Input
FACTORY EQUIPPED FOR PROPANE GAS:
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Orifi ce size
Altitude
Maximum Input
Minimum Input
Model U39E-LP12: Convertible for Altitude 0-4500 ft.
Orifi ce size
Maximum Input
Minimum Input
ELECTRICAL SUPPLY/ALIMENTATION ÉLECTRIQUE
115V_60HZ less than/Moins de 2 AMP.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title
24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA
501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited
by local codes. See owner's manual for details. Optional Fan (Part# 910-331/P).
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construc-
tion and Safety Standard. Si ces normes ne sont pas pertinentes, se reporter à la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou
NFPA 501C Standard for Recreational Vehicles.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée mobile installée à demeure si les
règlements locaux le permettent. Voir le manuel d'utilisation pour plus de renseignements. Ventilateur en option (Pièce n 910/331/P)
This vented gas fi replace heater is not for use with air fi lters.
For use with glass doors certifi ed with the appliance only
For Use Only with Barrier (Part #732-929) Follow installation instructions.
Utiliser uniquement avec l'écran de sécurité (n° 732-929). Suivre les consignes d'installation.
VENTED GAS FIREPLACE HEATER -
ÉVACUATION - NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE. CATÉGORIE I.
CANADIAN ENERGY
CSA P.4.1 Fireplace Efficiency (FE) / Efficacité énergétique des foyers (EEF) CSA P.4.1
PERFORMANCE
VERIFIED
Natural Gas / Gaz naturel 73.45%
RENDEMENT
Propane Gas / Gaz propane 75.68%
ÉNERGÉTIQUE
VÉRIFIÉ
EP5011169
For the State of Massachusetts, installation and repair
must be done by a plumber or gas fitter licensed in
the Commonwealth of Massachusetts.
For the State of Massachusetts, flexible connectors
shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances
individual manual shut-off must be a t-handle type
valve.
The State of Massachusetts requires the installation
of a carbon monoxide alarm in accordance with NFPA
720 and a CO alarm with battery back up in the same
room where the gas appliance is installed.
ANSI Z21.88-2019 • CSA 2.33-2019 / CSA 2.17-2017
Model U39E-NG12
APPAREIL FONCTIONNANT AU GAZ NATUREL :
Pression d'alimentation minimale
5"
WC/C.E. (1.25kPa)
Pression manifold élevée
3.5"
WC/C.E. (0.87kPa)
1.6"
WC/C.E. (0.40kPa)
Pression manifold basse
Fonctionnant à une altitude entre 0 et 2000 pi :
#32
DMS
Dimensions de l'orifi ce
0-2000
ft/pi
(0-610)
Altitude
38,000
Btu/h
(11.1Kwh)
Débit calorifi que maximal
26,000
Btu/h
(7.61Kwh)
Débit calorifi que minimal
Convertible pour altitude entre 0 et 4500 pi :
Dimensions de l'orifi ce
#35
DMS
0-4500 ft/pi
(0-1370m)
Altitude
35,000
Btu/h
(10.26Kw)
Débit calorifi que maximal
24,000
Btu/h
(7.03Kwh)
Débit calorifi que minimal
Model U39E-LP12
APPAREIL FONCTIONNANT AU PROPANE :
11"
WC/C.E. (2.74Kpa)
Pression d'alimentation minimale
Pression manifold élevée
10"
WC/C.E. (2.49Kpa)
6.4"
WC/C.E. (1.59Kpa)
Pression manifold basse
49
DMS
Dimensions de l'orifi ce
0-2,000 ft/pi
(0-610m)
Altitude
38,000
BTU/h
( 11.1Kw/h)
Débit calorifi que maximal
30,000
BTU/h
(8.79Kw/h)
Débit calorifi que minimal
Convertible pour altitude entre 0 et 4500 pi :
#51
DMS
Dimensions de l'orifi ce
32,500
Btu/h
(9.52Kwh)
Débit calorifi que maximal
26,000
Btu/h
(7.61Kwh)
Débit calorifi que minimal
:
FPI Fireplace Products International Ltd. Delta, BC, Canada
Made in Canada / Fabriqué au Canada
N e pas utiliser de fi ltre à air avec ce foyer au gaz à évacuation
À utiliser uniquement avec les portes vitrées certifiées avec l'appareil l
NOT FOR USE WITH SOLID FUELS. CATEGORY I.

Decal location

NOTE: Regency
improved. Check the label on the unit and if there is
a difference, the label on the unit is the correct one.
Duplicate serial #
DO NOT REMOVE THIS LABEL /
NE PAS ENLEVER CETTE ÉTIQUETTE
Modèle U39E-NG12
Minimum Clearances to Combustibles
Dégagements minimaux aux matériaux combustibles
A 7-1/2"
B 6"
E 2"
Min. Ceiling Height from top of unit / Min. Plafond
Hauteur depuis le haut de l'appareil:
36" / 914 mm
Modèle U39E-LP12
o
.
FOYER AU GAZ À
Lower access panel and locate the rating located
on the back of the access panel (see image
below).
DO NOT REMOVE FROM THE UNIT.
Regency
U39E-12 ULTIMATE™ Freestanding Gas Stove
®
safety decal
units are constantly being
®
533
533
Serial No./No de série
/190mm
/150mm
/50mm
920-136b
Part #: 920-136b
Colour:
Black on Grey
is in red as per
Material:
2ml silver matt
Size:
100%
June 26/19: Created Deca
Aug. 23/22: Updated wor
* Printer: Start serial seq
|
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ultimate u39eUltimate u39e-lp12

Table of Contents