Important Information; Specifications; Information For Mobile/Manufactured Homes After First Sale - Regency Ultimate U39E-NG12 Owners & Installation Manual

Freestanding gas stove
Table of Contents

Advertisement

Important Message
SAVE THESE INSTRUCTIONS
The ULTIMATE Direct Vent Freestanding Gas
Stove must be installed in accordance with these
instructions. Carefully read all the instructions in this
manual first. Consult the building authority having
jurisdiction to determine the need for a permit prior
to starting the installation.
Note: Failure to follow the instructions
could cause a malfunction of
the heater which could result in
death, serious bodily injury, and/
or property damage. Failure to
follow these instructions may also
void your fire insurance and/or
warranty.
Note:
T h e s e i n s t r u c t i o n s t a k e
p r e c e d e n c e o v e r S i m p s o n
D u r a - V e n t
i n s t r u c t i o n s .

Specifications

Fuels: U39E-NG12 is approved for use with natural
gas.
U39E-LP12 is approved for use with liquefied
petroleum gases (propane).
Electrical: 115V A.C. system.
Circulation Fan: Variable speed, 125/75.
Log Sets: Ceramic fibre, 7 per set.
Vent System: Coaxial (6-5/8" outer / 4" inner liner)
rigid flue and termination cap.
Information For Mobile/
Manufactured Homes After
First Sale
This Regency
product has been tested and listed
®
by Warnock Hersey/Intertek as a Direct Vent Wall
Furnace to the following standards: CSA 2.17 and
ANSI Z21.88/CSA 2.33.
This Direct Vent System Appliance must be
installed in accordance with the manufacturer's
installation instructions and the Manufactured Home
Construction and Safety Standard, Title 24 CFR,
Part 3280, or the current Standard of Fire Safety
Criteria for Manufactured Home Installations, Sites,
and Communities ANSI/NFPA 501A, and with CAN/
CSA Z240-MH Mobile Home Standard in Canada.
This appliance installation must comply with the
manufacturer's installation instructions and local
codes, if any. In the absence of local codes follow
the current National Fuel Gas Code, ANSI Z223.1
and the current National Electrical Code ANSI/
NFPA 70 in the U.S.A., and the current CSA B149
.1 Gas Installation Code and the current Canadian
Electrical Code CSA C22.1 in Canada.
This Regency
Mobile/Manufactured
®
Home Listed appliance comes factory
equipped with a means to secure the unit.
This Regency
Mobile/Manufactured
®
Home listed appliance comes equipped
with a dedicated #8 ground lug to which
an 18 gauge copper wire from the steel
chassis ground must be attached.
This appliance may only be installed
in an aftermarket permanently
located, manufactured (mobile)
home, where not prohibited by local
codes.
This appliance is only use with
the type of gas indicated on the
rating plate. This appliance is not
convertible for use with other gases,
unless a certified kit is used.
Regency
1. Provide adequate clearances for servicing,
proper operation and around the air openings
into the combustion chamber.
2. The appliance may be installed on a flat, solid,
continuous surface (e.g. wood, metal, concrete).
This may be the floor, or it can be raised up on
a platform to enhance its visual impact. The
appliance may be installed on carpeting, tile,
wood flooring or other combustible material,
because the appliance's metal pedestal base
extends the full width and depth of the appliance.
The ULTIMATE Direct Vent Freestanding Gas
Stove can be installed in a wide variety of ways
and will fit nearly any room layout. It may be
installed in a recessed position, framed out into
the room, or across a corner.
3. The ULTIMATE Direct Vent Freestanding Gas
Stove is approved for alcove installations, which
meet the clearances as listed in the "Locating
Your Ultimate Gas Stove" section. This unit is
approved for manufactured home installations,
see "Rigid Pipe Venting Arrangements" section
for the required vent arrangements. If installed
into a manufactured home the unit must be
bolted down to the floor.
4. This appliance is Listed for bedroom installations
when used with a Listed Millivolt Thermostat.
Some areas may have further requirements,
check local codes before installation.
5. This appliance is Listed for Alcove installations,
maintain minimum Alcove clearances as follows,
minimum width of 48" (1219mm), a maximum
depth of 36" (914mm), and minimum ceiling
height of 64"(1626mm).
6. We recommend that you plan your installation on
paper using exact measurements for clearances
and floor protection before actually installing this
appliance. Have a qualified building inspector
review your plans before installation.
U39E-12 ULTIMATE™ Freestanding Gas Stove
®
installation
|
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ultimate u39eUltimate u39e-lp12

Table of Contents