Ginlong SOLIS S5-GC50K Installation And Operation Manual page 35

Solis three phase inverter
Table of Contents

Advertisement

10. Specifications
Model
Max. DC input voltage (Volts)
Rated DC voltage (Volts)
Start-up voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
Max short circuit input current (Amps)
MPPT number/Max input strings number
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
Rated grid voltage (Volts)
Rated grid output current (Amps)
Max. output current (Amps)
Power Factor (at rated output power)
THDi (at rated output power)
Rated grid frequency (Hertz)
Max.efficiency
EU efficiency
Dimensions (W*H*D)
Weight
Topology
Self consumption (night)
Operating ambient temperature range
Relative humidity
Ingress protection
Cooling concept
Max.operation altitude
Grid connection standard
Safty/EMC standard
DC connection
AC connection
Display
Communication connections
Warranty
.68.
S5-GC36K-LV
1100
360
195
180...1000
4*32
4*40
4/8
36000
36000
36000
3/(N)/PE, 220
94.5
94.5
0.8leading~0.8lagging
<3%
50/60
98.4%
98.0%
691*578*338mm
54.5kg
Transformerless
<1W
-25℃...+60℃
0~100%
IP66
Intelligent redundant cooling
4000m
UL 1741, IEEE 1547, NBR 16149,
NBR 16150, C10-11, REN 342
IEC 62109-1/-2, IEC62116 &IEC 61000-6-1/-2/-3/-4
MC4 connector
OT Terminal (max 70 mm²)
LCD, Capacitive touch buttons
RS485/USB, Optional: Wi-Fi, GPRS
5 years (extand to 20 years)
10. Specifications
Model
Max. DC input voltage (Volts)
Rated DC voltage (Volts)
Start-up voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
Max short circuit input current (Amps)
MPPT number/Max input strings number
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
Rated grid voltage (Volts)
Rated grid output current (Amps)
Max. output current (Amps)
Power Factor (at rated output power)
THDi (at rated output power)
Rated grid frequency (Hertz)
Max.efficiency
EU efficiency
Dimensions (W*H*D)
Weight
Topology
Self consumption (night)
Operating ambient temperature range
Relative humidity
Ingress protection
Cooling concept
Max.operation altitude
Grid connection standard
Safty/EMC standard
DC connection
AC connection
Display
Communication connections
Warranty
S5-GC37.5K-LV
1100
360
195
180...1000
4*32
4*40
4/8
37500
37500
37500
3/(N)/PE, 220
98.4
98.4
0.8leading~0.8lagging
<3%
50/60
98.4%
98.0%
691*578*338mm
54.5kg
Transformerless
<1W
-25℃...+60℃
0~100%
IP66
Intelligent redundant cooling
4000m
UL 1741, IEEE 1547, NBR 16149,
NBR 16150, C10-11, REN 342
IEC 62109-1/-2, IEC62116 &IEC 61000-6-1/-2/-3/-4
MC4 connector
OT Terminal (max 70 mm²)
LCD, Capacitive touch buttons
RS485/USB, Optional: Wi-Fi, GPRS
5 years (extand to 20 years)