10. Specifications
Model
Max. DC input voltage (Volts)
Rated DC voltage (Volts)
Start-up voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
Max short circuit input current (Amps)
MPPT number/Max input strings number
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
Rated grid voltage (Volts)
Rated grid output current (Amps)
Max. output current (Amps)
Power Factor (at rated output power)
THDi (at rated output power)
Rated grid frequency (Hertz)
Max.efficiency
EU efficiency
Dimensions (W*H*D)
Weight
Topology
Self consumption (night)
Operating ambient temperature range
Relative humidity
Ingress protection
Cooling concept
Max.operation altitude
Grid connection standard
Safty/EMC standard
DC connection
AC connection
Display
Communication connections
Warranty
.64.
S5-GC60K-HV
1100
720
195
180...1000
6*32
6*40
6/12
60000
66000
66000
3/PE, 480
72.2
79.4
0.8leading~0.8lagging
<3%
50/60
98.7%
98.4%
691*578*338mm
54.5kg
Transformerless
<1W
-25℃...+60℃
0~100%
IP66
Intelligent redundant cooling
4000m
VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1,
UTE C15-712-1, NRS 097-1-2, G98, G99,
EN 50549-1/-2, RD 1699, UNE 206006,
UNE 206007-1, IEC61727,DEWA
IEC 62109-1/-2, IEC62116 &IEC 61000-6-1/-2/-3/-4
MC4 connector
OT Terminal (max 70 mm²)
LCD, Capacitive touch buttons
RS485/USB, Optional: Wi-Fi, GPRS
5 years (extand to 20 years)
10. Specifications
Model
Max. DC input voltage (Volts)
Rated DC voltage (Volts)
Start-up voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
Max short circuit input current (Amps)
MPPT number/Max input strings number
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
Rated grid voltage (Volts)
Rated grid output current (Amps)
Max. output current (Amps)
Power Factor (at rated output power)
THDi (at rated output power)
Rated grid frequency (Hertz)
Max.efficiency
EU efficiency
Dimensions (W*H*D)
Weight
Topology
Self consumption (night)
Operating ambient temperature range
Relative humidity
Ingress protection
Cooling concept
Max.operation altitude
Grid connection standard
Safty/EMC standard
DC connection
AC connection
Display
Communication connections
Warranty
S5-GC70K-HV
1100
720
195
180...1000
6*32
6*40
6/12
70000
77000
77000
3/PE, 480
84.2
92.6
0.8leading~0.8lagging
<3%
50/60
98.7%
98.4%
691*578*338mm
54.5kg
Transformerless
<1W
-25℃...+60℃
0~100%
IP66
Intelligent redundant cooling
4000m
VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1,
UTE C15-712-1, NRS 097-1-2, G98, G99,
EN 50549-1/-2, RD 1699, UNE 206006,
UNE 206007-1, IEC61727,DEWA
IEC 62109-1/-2, IEC62116 &IEC 61000-6-1/-2/-3/-4
MC4 connector
OT Terminal (max 70 mm²)
LCD, Capacitive touch buttons
RS485/USB, Optional: Wi-Fi, GPRS
5 years (extand to 20 years)
.65.