4. Comm. & Monitoring
There are 2 communication ports on the inverter.
One is a 4-Pin COM port and the other is a 16-Pin COM port.
The 4-Pin COM port is used to connect Solis datalogging sticks
(Please refer to manuals of Solis datalogging sticks for details).
The 16-Pin COM port is used for multiple inverter daisy chain connection/DRM connection/
Logic Interface Connection/Meter connection.
The inverter package will include a 16-Pin COM connector to be used on this 16-Pin
COM port. The Pin definition is shown below. Facing the connector, Pin 1 is on the left
of the first row. The rest polarity is showing in below diagram.
Figure 4.1 16pin COM Connector
The following is the assembly diagram of the 16-Pin COM connector.
B
A
A-Main cable (Diameter: 4-6mm)
B-Locking Nut (Torque: 3.5-4N.m)
C- Sleeve
D-COM Wire (Dimension: 0.75-3mm², stripping length: 10-12mm)
E-Locking Screw (Torque: 0.4-0.6N.m)
F-Connector
.26.
Pin
Definition
Pin
Definition
1
Meter RS485-A
9
DRM1/5
2
10
Meter RS485-B
DRM 2/6
COM1 485-A
DRM 3/7
3
11
4
COM1 485-B
12
DRM 4/8
\
RefGen
5
13
6
COM2 485-A
14
Com/DRM0
7
COM2 485-B
15
V+, 12V
8
\
16
V-, GND
F
C
D
E
Figure 4.2
4. Comm. & Monitoring
Connect Steps:
1. Lead the main cable through the locking nut and the sleeve.
2. Strip the COM wires and insert into corresponding pin terminals.
Then fasten the locking screws for the pin terminals.
3. Push the sleeve onto the connector and fasten the locking nut on the end of the sleeve.
4. Connect the connector to the 16-Pin COM port at the bottom of the inverter.
Disconnect Steps:
1. Press the button on both sides of the connector and pull the connector to disconnect from
the COM port.
Figure 4.3
Figure 4.4