TROUBLESHOOTING
Control Board
Fault Code
LED Display
22
E22
23
E23
24
E24
E25
25
E26
26
27
E27
28
E28
29
E29
30
E30
31
E31
2
E32
32*
2
-
33*
34
E34
66
Transmitted Climate
Thermostat Fault
Talk Message
This error indicates the equipment
is experiencing frequent high
HI DISCH TEMP
discharge temperature faults.
Discharge thermistor is not put on
correct position.
The control has detected that the
Discharge Temperature Sensor is
DISCH TEMP FAIL
out of range.
HPS OPEN
The high pressure switch is open.
The outdoor air temperature
AIR SENSOR FLT
sensor is open or shorted.
The control determines that the
PRESSURE SENSOR
pressure sensor is not reacting
properly.
The control detects that the
COIL TEMP FAIL1
Outdoor Defrost Sensor is out of
range.
The control has detected that the
COIL TEMP FAIL2
Outdoor Coil Temperature Sensor
is out of range.
The control has detected that the
LIQ TEMP FAIL
Liquid Temperature Sensor is out
of range.
Indicates the control board may
OD CTRL FAIL3
need to be replaced.
The control has detected high
HI LEAK CURRENT
leakage current (high voltege).
This error indicates the equipment
is experiencing high temperature
HI TEMP CTRL1
faults on the outdoor control board.
This error indicates the equipment
is experiencing high temperature
faults on the outdoor control board.
HI TEMP CTRL2
Control has determined continued
operation is acceptable. This
indicates they may be a problem
with the equipment.
Board detected a high current
CURRENT SPIKE
condition. This indicates the
potential for a short circuit.
OUTDOOR UNIT ERROR CODES
Probable Causes
● Discharge thermistor inoperable or
● Check discharge thermistor resistance and
improperly connected
connections; Repair/replace as needed
● Discharge thermistor is put on
● Check discharge thermistor position
incorrect position or off
● Check refrigerant charge level; Adjust if
● Low refrigerant charge
needed
● Overcharge
● Check the compressor; Repair/replace if
● Faulty compressor
needed
● Discharge thermistor inoperable or
● Check discharge thermistor resistance and
improperly connected
connections; Repair/replace as needed
● High pressure switch (HPS)
● Check resistance on HPS to verify operation;
inoperable
Replace if needed
● Faulty outdoor thermistor sensor or
● Inspect and test sensor; Replace sensor if
disconnect
needed
● Low pressure sensor inoperable or
● Check the connection to low pressure
not properly connected
sensor; Repair/replace if needed
● Outdoor defrost thermistor inoperable
● Check the connection to OD defrost
or not properly connected
thermistor; Repair as needed
● Outdoor coil thermistor inoperable or
● Check the connection to OD coil thermistor;
not properly connected
Repair/replace if needed
● Liquid thermistor inoperable or not
● Check the connection to liquid thermistor;
properly connected
Repair/replace if needed
● Wiring to control board disconnected
● Check wiring to control board; Repair as
● Faulty control board
needed
● Noise
● Replace control board if necessary
●Check ground screws/lugs and wiring;
● Improper ground
Repair/replace if needed
● Faulty compressor
● Check the compressor; Repair/replace if
needed
● Cycle power; re-try during usable ambient
temperature range
● Ambient air conditions too high
● Verify cooling bracket screws in place and
● Cooling bracket screw(s) missing or
secure; Secure fasteners as needed (2-4 ton
not properly fastened (2-4 ton only)
only)
● No or poor thermal grease coating
● Check thermal grease inside cooling bracket
between cooling plumbing and cooling
on control board; Apply additional grease as
bracket on control board (2-4 ton only)
needed
● Outdoor fan low speed (5 ton only)
● Check outdoor fan motor & wiring;
● No flow or limited flow through control
Repair/replace if needed (5 ton only)
board cooling circuit (potential
● Check for restriction in line
restriction in line or low refrigerant) (2-4
● Check refrigerant charge level; Adjust if
ton only)
needed (2-4 ton only)
● Stop valve not completely open (2-4
● Check the opening of stop valve, should be
ton only)
full open;
Repair/replace if needed (2-4 ton only)
● Cycle power; re-try during usable ambient
temperature range
● Ambient air conditions too high
● Verify cooling bracket screws are in place
● Cooling bracket screw(s) missing or
and secure; Secure fasteners as needed (2-4
not properly fastened (2-4 ton only)
ton only)
● No or poor thermal grease coating
● Check thermal grease inside cooling bracket
between cooling plumbing and cooling
on control board; Apply additional grease as
bracket on control board (2-4 ton only)
needed
● Outdoor fan low speed (5 ton only)
● Check outdoor fan motor & wiring;
● No flow or limited flow through control
Repair/replace if needed (5 ton only)
board cooling circuit (potential
● Check for restriction in line
restriction in line or low refrigerant) (2-4
● Check refrigerant charge level; Adjust if
ton only)
needed (2-4 ton only)
● Stop valve not completely open (2-4
● Check the opening of stop valve - it should
ton only)
be fully
open; Repair/replace if needed (2-4 ton only)
● Check power supply for in-rush current
during start-up or steady state operation
● Current spike in supply
● Check the opening of stop valve, should be
● Stop valve not completely open
full open; Repair/replace if needed
● The compressor wire is lost phase
● Check the wire between control board and
● Faulty control board
compressor
● Faulty compressor
● Replace control board if necessary
● Check the compressor; Repair/replace if
needed
Corrective Actions