SERVICING
Upon start up in emergency mode the circuit board may display an "Ed" error. This is an indication that the DIP switches
on the control board need to be configured in accordance with the Electric Heating Airflow Table. Configuring the DIP
switches to the unit will clear the error code.
Heater Kit
Selec�on
AMVE24BP14
No Heater
-
First
3
Second
5
Third
6
Fourth
8
Fi�h
10
Sixth
X
Seventh
X
Emergency Mode
Emergency Mode
NOTE: Default factory settings are marked with *.
50
Switch Bank DS-3
Indoor Control Board Se�ngs
Heater kW
AMVE36CP14
AMVE48DP14
-
-
5
5
6
6
8
8
10
10
15
15
19
20
X
X
Switch Bank DS-6
Indoor Control Board Settings
Function
Normal operation
Cooling Emergency mode/Fan only Emergency mode
Heating Emergency mode (High heat level)
Heating Emergency mode (Low heat level)
Switch Bank DS-2
Outdoor Control Board Settings
Function
Normal operation
Cooling Emergency mode (Low cool Level)
Cooling Emergency mode (Medium cool Level)
Cooling Emergency mode (High cool level)
S-9
AMVE60DP14
-
OFF*
5
ON
6
ON
8
ON
10
ON
15
ON
20
ON
25
ON
Dip Switch Se�ng
S-10
S-11
S-12
OFF*
OFF*
OFF*
ON
ON
ON
ON
ON
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
OFF
ON
S-21
S-22
OFF*
OFF*
ON
OFF
OFF
ON
ON
ON
S-1
S-2
ON*
ON*
ON
OFF
OFF
ON
OFF
OFF