7. ANODE SHORTED

Anode
0 days 0 hrs 0 mins ago
Error Code: CC-B
The Powered Anode is shorted to
earth ground or the tank.
The control indicates a problem
with the anode
CHECK/ REPAIR:
• Bent anode shorting to tank.
• Contamination (solder, loctite, water, Etc.) between anode top and surrounding metal.
• Power anode shorted to ground at wire connection. See Powered Anodes section shown under "No Water"
on page 25.
S
horted
ADVANCED
BACK
Servicing should only be performed by a Qualified Service Technician
CAUSES:
• The controller has detected a low resistance or
short to earth ground or the tank.
27