Advantech PCA-6186VE User Manual page 117

Table of Contents

Advertisement

;-----------------------------------------------------------
Dec dx
Mov al,0f5h
Out dx,al
Inc
dx
In
al,dx
And al,not 08h
Out dx,al
;-----------------------------------------------------------
Dec dx
Mov al,0f6h
Out dx,al
Inc
dx
Mov al,10
Out dx,al
;-----------------------------------------------------------
Dec dx
Mov al,0aah
Out dx,al
2.
Enable watchdog timer and set 5 minutes as timeout interval
;-----------------------------------------------------------
Mov dx,2eh
Mov al,87h
Out dx,al
Out dx,al
;-----------------------------------------------------------
Mov al,07h
Out dx,al
Inc
dx
Mov al,08h
Out dx,al
PCA-6186 User's Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
; Set second as counting unit
; Set timeout interval as 10 seconds and start counting
; lock W83627HF
; unlock W83627H
; Select registers of watchdog timer