Download Print this page

F&F LE-05d Quick Start Manual

Electric energy meter, without neutral wire

Advertisement

Quick Links

LE-05d
Electric energy meter,
without neutral wire
Do not dispose of this device in the trash along with other waste! According to the
Law on Waste, electro coming from households free of charge and can give any amo-
unt to up to that end point of collec� on, as well as to store the occasion of the pur-
chase of new equipment (in accordance with the principle of old-for-new, regardless
of brand). Electro thrown in the trash or abandoned in nature, pose a threat to the
environment and human health.
Purpose
The LE-05d is a static (electronic) calibrated electricity meter,
used as a sub-meter for indicating the consumed three-phase
AC active electricity in the Arona metering system.
Functioning
A special electronic system under the influence of current flow
and applied voltage in each phase generates pulses in propor-
tion to the electricity consumed in this phase.
Phase energy consumption is indicated by flashing the corre-
sponding LED (A and C). The sum of the three phases of pulses
indicated by a flashing LED is converted to energy taken in the
entire three-phase system, and its value is determined by the
segment LCD display.
Numbers after the decimal point indicate decimals (.1 kWh =100
Wh).
F&F Filipowski L.P.
Konstantynowska 79/81, 95-200 Pabianice, POLAND
phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71
www.fif.com.pl; e-mail: biuro@fif.com.pl
- 1 -

Advertisement

loading

Summary of Contents for F&F LE-05d

  • Page 1 Electro thrown in the trash or abandoned in nature, pose a threat to the environment and human health. Purpose The LE-05d is a static (electronic) calibrated electricity meter, used as a sub-meter for indicating the consumed three-phase AC active electricity in the Arona metering system.
  • Page 2: Pulse Output

    Measured values Active energy consumed [kWh] Pulse output The meter is equipped with pulse output. This allows you to con- nect another pulse device (SO) that reads pulses generated by the meter. No additional connected equipment is required for proper operation of the meter. Front description - 2 -...
  • Page 3 Sealing The meter has sealable input and output terminal covers to pre- vent any attempts to bypass the meter. Meter number The meter is marked with individual serial number allowing its unambiguous identification. The marking is laser engraved and cannot be removed). - 3 -...
  • Page 4 Meter number cont. Mounting 1. Disconnect the power supply. 2. The indicator mounted on a rail in the distribution box. 3. Use a screwdriver to unscrew the screws and remove the front counter terminal covers. 4. Connect the voltages of the phases to be monitored as indica- ted to the terminals 1 (L1), 3 (L2), 5 (L3).
  • Page 5: Wiring Diagram

    Wiring diagram 1 L1 phase 5 L3 phase 2 L1 phase 6 L3 phase 3 L2 phase 8 pulse output (–) 4 L2 phase 9 pulse output (+) - 5 -...
  • Page 6 Technical data installation 3-wire rated voltage 3×400 V minimum measured current 0.04 A base current 10 A maximum current 100 A voltage measuring range 160÷265 V measurement accuracy (IEC62052) 1st class rated frequency 50 Hz insulation protection class housing PC+ABS material own power consumption <10 VA;...
  • Page 7: Warranty

    Dimensions Warranty F&F products are covered by a 24-month warranty from the date of purchase. The warranty is only valid with proof of purchase. Contact your dealer or contact us directly. CE declaration F&F Filipowski L.P. declares that the device is in conformity with the essential requirements of the Low Voltage Directive (LVD) 2014/35/EU and the Electromagnetic Compatibility (EMC) Directive 2014/30/UE.
  • Page 8 General work safety conditions » Please read the instructions carefully before installation. » The device should be installed and operated by qualified per- sonnel who are familiar with its design, operation, and asso- ciated risks. » Do not install a meter that is damaged or incomplete. »...