40
en | Camera
Auto pan left limit
Sets the left Auto Pan limit of the camera. Use the preview window to move the camera to the
left pan limit and click the button. The camera will not move past this limit when in Auto Pan
Between Limits mode (AUX 2 ON).
Auto pan right limit
Sets the right Auto Pan limit of the camera. Use the preview window to move the camera to
the right pan limit and click the button. The camera will not move past this limit when in Auto
Pan Between Limits mode (AUX 2 ON).
Tilt up limit
Sets the upper tilt limit of the camera. Use the preview window to move the camera to the tilt
limit and click the button.
Pan limit left
Set the appropriate pan limit on the left.
Pan limit right
Set the appropriate pan limit on the right.
Tour A / Tour B
Starts and stops the recording of a recorded (guard) tour.
The camera can make up to two (2) recorded tours. A recorded tour saves all manual camera
movements made during the recording, including its rate of pan, tilt and zoom speeds, and
other lens setting changes. The tour does not capture camera video during the recording of
the tour.
Note 1: You can save a total of 15 minutes of recorded actions between the two tours.
To record a tour:
1.
2.
3.
4.
5.
Note: Tour B is now intended for use with the 'IVA while moving' functions.
Compass
The camera allows a user to display the compass heading of the camera in the lower-right
corner of the image display. The camera displays the cardinal or intercardinal (N, NE, E, SE, S,
SW, W, NW) heading in which the camera is pointing.
Notice!
The compass feature is not compatible with Bosch's Intelligent Tracking feature. If Intelligent
Tracking is activated, the camera automatically disables the display of the compass heading.
Once Intelligent Tracking is deactivated, the camera returns the compass heading to the
display.
You must first calibrate the camera to North before the camera displays accurate compass
headings. The camera uses this calibration, usually set to magnetic North, as the zero degree
pan position and as the North compass heading. The camera then displays the compass
heading based on the number of degrees from the North calibration point.
To set the North calibration point:
1.
2.
3.
2017.11 | 0.20 | F.01U.349.011
Click the Start Recording button. The system prompts you to overwrite the existing tour.
Click Yes to overwrite the existing tour movements.
Click the View Control link, under the image cameo, to access the directional and zoom
controls.
Use the View Control dialog box to make the necessary camera movements.
Click the Stop Recording button to save all actions.
Determine the North compass heading, then move the camera to that position.
Select the radio button On for the parameter Compass.
Click the button next to North point to set the calibration point.