Table of Contents

Advertisement

Quick Links

MIC IP fusion 9000i
MIC-9502
en
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Bosch MIC-9502

  • Page 1 MIC IP fusion 9000i MIC-9502 User Manual...
  • Page 3: Table Of Contents

    User Management Date/Time Display Stamping GB/T 28181 Web Interface Appearance LIVE Functions Camera Installer Menu 6.1.1 Positioning Encoder Profile Encoder Streams Privacy Masks Picture Settings Picture Settings Thermal Lens Settings Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 4 Network Access 10.3 DynDNS 10.4 Advanced 10.5 Network Management 10.6 Multicast 10.7 Image Posting 10.8 Accounts 10.9 IPv4 Filter 10.10 Encryption Service 11.1 Maintenance 11.2 Licenses 11.3 Certificates 11.4 Logging 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 5 12.2 Using Intelligent Tracking 12.3 Uploading a User Logo 12.4 Azimuth, Elevation, and Compass Directions 12.5 Using the Wiper/Washer (Bosch Protocol) 12.6 Using the Wiper/Washer (Pelco Protocol) 12.7 Flat Field Correction on Thermal Cameras Understanding the Fusion Feature 13.1 Video content analytics on the Live page 13.2...
  • Page 6: Browser Connection

    If you cannot connect, the unit may have reached its maximum number of connections. Depending on the device and network configuration, each unit can have up to 50 web browser connections, or up to 100 connections via Bosch Video Client or Bosch Video Management System.
  • Page 7 (“service”) and the service-level password every time that they access the device. Fill in the fields User name and Password. Click OK. If the password is correct, the desired page appears. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 8: System Overview

    Configuration To configure the unit, click this icon. Links To navigate to the Bosch download store, click this icon. To get context sensitive help for a particular page, click this icon. Note: None of the pages are accessible until after you set a service-level password.
  • Page 9: Operation Via The Browser

    Click the - button to zoom out. Iris Click (Iris close) to close the iris. Click (Iris open) to open the iris. Focus Click to focus near. Click to focus far. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 10: Pre-Positions

    To stop a tour, click a directional control in the View Control tab. Note: Tour B is now intended for use with the 'IVA while moving' functions. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 11: Recording Status

    ) that is below the lower-left corner of the live video image. 3.1.13 Audio communication Audio can be sent and received via the Live page if the unit and the computer support audio. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 12: Storage, Cpu And Network Status

    Watermark invalid Indicates that the watermark is not valid. Motion alarm Indicates that a motion alarm has occurred. Storage discovery Indicates that recorded video is being retrieved. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 13: Playback Via Browser

    Click the alarm jump buttons to go from one alarm event to the next or to the previous one. Red bars indicate the points in time where alarms were triggered. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 14 The buttons have the following functions: – Start/Pause playback – Select the playback (forward or backward) speed using the speed regulator – Step forward or backward frame-by-frame when paused (small arrows) 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 15: General

    A check mark in this check box indicates that at least one certificate is loaded onto the camera. If no certificates are loaded, then “No certificate installed” appears to the right of the text. The Escrypt certificate is a root certificate for Bosch Security Systems that proves that the device meets the following criteria: –...
  • Page 16: Date/Time

    Note: It is important that the date/time is correct for recording. An incorrect date/time setting could prevent correct recording. Device time zone Select the time zone in which your system is located. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 17: Display Stamping

    To place a logo on the image, select and upload an uncompressed .bmp file with a maximum size of 128x128 pixels and 256 colors to the camera. Its position on the image can then be selected. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 18 In the Position (XY) fields, enter the values for the desired position. Title region Select On to set or to edit the position of the title region on the OSD. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 19: T 28181

    H.264 elementary stream Select this checkbox to select or to enable the H.264 elementary stream. Registration timeout Enter a value (in milliseconds) for the registration timeout. The default is 3600. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 20 Enter the ID of the device. Device port Enter the number of the device port. The default is 5060. Password Enter the appropriate password. Alarm device ID Enter the ID of the alarm device. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 21: Web Interface

    The following table identifies the metadata that appear. Image being viewed Imager that Detected Object Resulting outlines Visible Visible imager Solid box Thermal imager Dotted box Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 22 You can specify the interval at which the individual images should be generated for the M- JPEG image on the Live page. JPEG quality You can specify the quality at which the JPEG images appear on the Live page. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 23: Live Functions

    LIVE page. If necessary, click Browse to find a suitable directory. Video file format Select a file format for the live page display. The MP4 format does not include metadata. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 24: Camera

    The Positioning feature describes the location of the camera and the perspective in the camera’s field of view. Perspective information is essential to Video Analytics, as it enables the system to compensate for the illusory smallness of distant objects. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 25 - vertical lines, ground lines and angles - you have placed in the camera. Clear the Calculate check box to enter a value manually or to refresh to the values provided by the camera itself. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 26 White lines represent the element as it should be positioned on the camera image based on the current calibration results or the determined calibration data. Horizon If the values correspond, areas on the camera image have a colored background. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 27: Encoder Profile

    84) or on the X-axis (Cartesian). If the camera is directed towards the north (WGS 84) or the Y-axis (Cartesian), the azimuth is 90°. Encoder Profile For the video signal encoding, you can select a code algorithm and you can change the presets for the profiles. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 28 Ideal for encoding on a DSL uplink where bit rate limitations are critical. Profile 8 3G Optimized Ideal for encoding on a 3G uplink where bit rate limitations are critical. If required, enter a new name for the profile. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 29 P-frames, and thus the maximum achievable quality of the P- frames. In the H.264-protocol, the Quantization Parameter (QP) specifies the degree of compression and thus the image quality for every frame. The lower the quantization of the P- Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 30: Encoder Streams

    The table below identifies the options available in the field Property for Stream 1 and the available options in the field Property for Stream 2, depending on the options selected for Stream 1. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 31 Profile 5 SD Balanced For an SD image, the video bit rate and frame quality are adjusted to a median profile for everyday use. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 32: Privacy Masks

    Draw the mask at 50% optical zoom or less for improved masking performance. Draw the mask 10% larger than the object to ensure that the mask completely covers the object as the camera zooms in and out. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 33: Picture Settings

    Blue Gain The blue gain adjustment offsets the factory white point alignment (reducing blue introduces more yellow). It is only necessary to change the white point offset for special scene conditions. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 34 This is accomplished by integrating the signal from a number of consecutive video frames to reduce signal noise. If you select this option, the camera disables Shutter automatically. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 35 Night mode priority Select the option to which the camera should give priority while in night mode: – Motion – Color (default) Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 36: Picture Settings Thermal

    Dark areas of the image might blend together, and light areas of the image might blend together. – If the Contrast enhancement level is too low, it may be difficult to distinguish between objects that have similar temperatures. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 37 Cooler parts of a scene will show blue. Hot objects will appear black and white. Rain The scene will show a mixture of very grainy colors depending on temperature. Rainbow The scene will show objects in a rainbow of colors depending on temperature. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 38: Lens Settings

    It is accomplished electronically, without any adjustment of the camera's optics, and no optical resolution is gained in the process. Select Standard (default) to enable this feature in standard mode. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 39: Ptz Settings

    This parameter allows the camera to stop tracking motion of certain objects, such as a tree or a flag swaying in the wind, in a confined area after the specified number of seconds. Settings range from 5 to 120. The default is 30. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 40 SW, W, NW) heading in which the camera is pointing. Notice! The compass feature is not compatible with Bosch’s Intelligent Tracking feature. If Intelligent Tracking is activated, the camera automatically disables the display of the compass heading. Once Intelligent Tracking is deactivated, the camera returns the compass heading to the display.
  • Page 41: Scene Mode Scheduler

    6.12 Sectors Sector The camera’s pan capability is divided into equal sectors (2, 4, 8, 16), as defined in PTZ Settings > Number of sectors, for a total of 360°. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 42: Miscellaneous

    Select a format for audio recording. The default value is AAC 48 kbps. You can select AAC 80 kbps, G.711 or L16 depending on the required audio quality or sampling rate. AAC audio technology is licensed by Fraunhofer IIS. (http://www.iis.fraunhofer.de/amm/) 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 43: Pixel Counter

    To change the shape of a zone, place the cursor over the edge of the zone, hold down the mouse button and drag the edge of the zone to the required position. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 44: Recording

    Note: For more information about Automatic Network Replenishment (ANR), refer to the White Paper “ANR 2.0 Automatic Network Replenishment (ANR),” available on the product page for your camera. Access the product page on the online product catalog from http:// www.boschsecurity.com/corporate/product-catalog/index.html. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 45: Activating And Configuring Storage Media

    Select the encoder profile setting that is to be used with stream 1 and 2 when recording. This selection is independent of the selection for live stream transmission. (The properties of the encoder profiles are defined on the Encoder Profile page.) Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 46 Select the alarm type that is to trigger an alarm recording: – Alarm input – Analysis alarm – Video loss Select the Virtual alarm sensors that are to trigger a recording, via RCP+ commands or alarm scripts, for example. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 47: Maximum Retention Time

    Once recording is underway, the Recording Profiles and Recording Scheduler pages are deactivated and the configuration cannot be modified. You can stop the recording activity at any time and modify the settings. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 48: Recording Status

    The graphic indicates the recording activity of the camera. You will see an animated graphic while recording is taking place. Recording Status Details of the recording status are displayed here for information. These settings cannot be changed. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 49: Alarm

    To enable Multicast operation, select the UDP option for the Video transmission parameter here and on Network Access. Stream Select the number of the stream from the drop-down list. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 50 The numbering follows the labeling of the video inputs on the device. Depending on the system configuration, the receiver can then select the other cameras as well. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 51: Video Content Analysis (Vca)

    Sensitivity and Trigger delay [s] can only be changed if Reference check is selected. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 52: Virtual Masks

    1. Select the number of the Virtual mask. In the video preview window, a dark grey rectangle appears with the text “Mask x,” where ‘x’ is the number of the mask. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 53: Audio Alarm

    Enter the IP address of a mail server that operates on the SMTP standard (Simple Mail Transfer Protocol). Outgoing e-mails are sent to the mail server via the address you entered. Otherwise leave the box blank (0.0.0.0). SMTP port Select the appropriate SMTP port. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 54: Alarm Task Editor

    This will overwrite all settings and entries on the other alarm pages. Click Examples under the Alarm Task Editor field to see some script examples. A new window opens. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 55: Alarm Rules

    Pre-position: defines a pre-position from shot 1-256. (Note: This option is not available for the input Time range.) Click the checkbox Enabled to activate the alarm. Click Set to save. The camera’s system activates the alarm rules. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 56: Interfaces

    Enter a name for the alarm output. Note: This name appears in the Digital I/O section of the Live page. Toggle Click the button to test the relay / output connection. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 57: Com1

    The number of data bits per character cannot be changed. Stop bits Select the number of stop bits per character. Parity check Select the type of parity check. Interface mode Select the desired protocol for the serial interface. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 58: Network

    If a DHCP server is employed in the network for the dynamic assignment of IP addresses, you can activate acceptance of IP addresses automatically assigned to the camera. Certain applications (Bosch Video Management System, Archive Player, Configuration Manager) use the IP address for the unique assignment of the unit. If you use these...
  • Page 59 The camera uses the TLS 1.0 encryption protocol. You may have to activate this protocol via your browser configuration. You must also activate the protocol for the Java applications (via the Java control panel in the Windows control panel). Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 60: Dyndns

    DynDNS.org and you must have registered the required host name for the unit on that site. Notice! Information about the service, registration process and available host names can be found at DynDNS.org. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 61: Advanced

    This field identifies any cloud-based services with which the camera communicates. – If you have registered the device on a cloud-based service such as Bosch Remote Portal, then this field identifies this fact (“Registered on Bosch Remote Portal”). Note: The button (Connect to Bosch Remote Portal) to connect to the device with that service is active.
  • Page 62: Network Management

    (DSCP). Enter a number between 0 and 252 as a multiple of four. For alarm video you can set a higher priority than for regular video and you can define a Post Alarm Time over which this priority is maintained. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 63: Multicast

    Enter the port address of the required stream here. Streaming Click the checkbox to activate multicast streaming mode for the relevant stream. An enabled stream is indicated by a check mark. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 64: Image Posting

    Fill in the maximum image width in pixels. Leave at 0 for automatic width selection. 10.8 Accounts Four separate accounts can be defined for posting and recording export. Type Select either FTP or Dropbox for the account type. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 65: Ipv4 Filter

    Enter the IPv4 address that you want to allow or block Mask 1 / 2 Enter the subnet mask for the appropriate IPv4 address. 10.10 Encryption If an encryption license is installed, this submenu gives access to the encryption parameters. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 66: Service

    Add a certificate/file to the file list Click Add. In the Add certificate window choose either: – Upload certificate to select a file that is already available: – Click Browse to navigate to the required file. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 67: Logging

    This window is for information only and cannot be modified. Keep this information at hand when seeking technical support. Select the text on this page with a mouse and copy it so that it can be pasted into an e-mail if required. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 68: Using Your Mic Camera

    Note: Tour B is now intended for use with the 'IVA while moving' functions. Preset Tours For scenarios that require the camera to be in continuous motion for most of the day, Bosch recommends that you set the camera in Preset Tour mode, moving between a desired set of presets.
  • Page 69: Using Intelligent Tracking

    Avoid neon lights, flashing lights, night time lights, and reflected light (from a window or mirror, for example). The flickering of these lights can affect the Intelligent Tracking operation. – Avoid motion from moving leaves/branches that present a persistent fixed motion. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 70 If an IVA rule is violated, it triggers the advanced tracking feature of the camera to start following the object / person that triggered the alarm. This allows the camera to track moving objects of interest without getting distracted by other moving objects in the scene. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 71 The camera will restart tracking if a target starts moving in the same area where the initial target stopped moving or if the camera detects an object moving along the last known trajectory. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 72: Uploading A User Logo

    Change the Camera Title Click General. Select Identification. Delete all of the text in the field Camera name. Rename the camera if desired. Click Set to save. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 73: Azimuth, Elevation, And Compass Directions

    Azimuth Zero point. Notice! Bosch recommends that only the installer calibrate the Azimuth Zero point. A recalibration to the Azimuth Zero point may cause inaccurate compass headings. Set the Azimuth Zero point: Determine the North compass heading, then move the camera to that position.
  • Page 74: Using The Wiper/Washer (Bosch Protocol)

    | Using your MIC Camera MIC IP fusion 9000i 12.5 Using the Wiper/Washer (Bosch Protocol) The "predefined position" for the wash/wipe function is preset 62. The installer must define preset 62 (preferably where the washer nozzle is located and can direct washer fluid towards the camera window) before using the wiper/washer function.
  • Page 75: Using The Wiper/Washer (Pelco Protocol)

    If you prefer not to see this freeze frame, you can turn off the Freeze Frame on Preposition in the PTZ Setup menu. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 76: Flat Field Correction On Thermal Cameras

    After several minutes of camera operation, the interval between FFC events is approximately 6 minutes. In case of constant motion in the scene, FFC may be delayed up to 12 minutes. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 77: Understanding The Fusion Feature

    Once alerted, operators can switch to the thermal image (below) of the scene, where they can easily see the objects creating the alarm. Hence, the metadata fusion feature provides enhanced situational awareness. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 78: Video Content Analytics On The Live Page

    VCA marks indicate. The following screenshots and tables provide more information. VCA marks on the visible image Image from visible imager with VCA metadata and trajectory lines 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 79 It is possible that the VCA on the image stream not currently being viewed may detect objects that are outside the field of view of the image stream that is being viewed. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 80 The arrows at the left edge of the image on the right indicate the vehicle that is out of view of the thermal imager but in view of the visible imager. In the image on the left, from the visible imager, a yellow box identifies the vehicle. 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 81: Troubleshooting

    – Adjust the Optical or thermal camera picture settings for your scene as described in Picture Settings, page 33 or Picture Settings Thermal, page 36 in the User Manual. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 82 (optical image). Camera reboots frequently or Test your camera with another power supply. intermittently Check the Bosch website for a software update that might address the issue. No OSD messages appear. Bosch’s Video SDK is required. Video management software from third parties does not use the SDK.
  • Page 83 The picture shows Check to see if the heat of images that aren’t objects is being reflected off present in the scene. a surface, causing thermal reflections. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 84 | Troubleshooting MIC IP fusion 9000i Customer Support and Service If this unit needs service, contact the nearest Bosch Security Systems Service Center for authorization to return and shipping instructions. Telephone: 800-366-2283 Fax: 800-366-1329 Email: cctv.repair@us.bosch.com Customer Service Telephone: 888-289-0096 Fax: 585-223-9180 Email: security.sales@us.bosch.com...
  • Page 85: Status Codes

    21 VAC and 30 VAC. Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 86 2. Verify the integrity/tightness of the external fasteners. Tighten where necessary. 3. If obvious damage is present, stop using the camera and contact the nearest Bosch Security Systems Service Center. 4. If no damage is evident, power the camera off and then on, and then evaluate operational performance.
  • Page 87 4. If damage to the seals is obvious, contact the nearest Bosch Security Systems Service Center. 5. If no obvious damage is found, power the camera off and then on. If the status code reappears, contact the nearest Bosch Security Systems Service Center.
  • Page 88 (and the window defrosters, for MIC IP fusion 9000i). If the log notes heater or defroster failure, contact the nearest Bosch Security Systems Service Center. 3. If operation is obstructed because of...
  • Page 89 If these actions do not resolve this problem, contact the nearest Bosch Security Systems Service Center. * Note: The MIC IP fusion 9000i camera requires a Bosch 95 W midspan (NPD-9501A) or a customer-tested/verified alternative. Caution! If you choose not to use a switch or midspan with the appropriate Power Sourcing Equipment (PSE) chip, then the MIC camera will not recognize the PoE as compliant, and the camera firmware may disable some or all functionality.
  • Page 90: Aux Commands

    Sector Blanking On/Off Privacy Masking On/Off Proportional Speed On/- Recalibrate Azimuth Compass On/Off Azimuth/Elevation Display On/Off Compass Points Display On/Off Record Tour A On/Off Record Tour B On/Off Wiper On/Off (Continuous) 2017.11 | 0.20 | F.01U.349.011 User Manual Bosch Security Systems...
  • Page 91 Activate color mode Rainbow --/Off Activate color mode Ocean On/-- Activate color mode Sunset --/Off Activate color mode Rain On/-- Activate color mode Arcus On/-- Activate color mode Inferno On/-- Execute Flat-field correction Bosch Security Systems User Manual 2017.11 | 0.20 | F.01U.349.011...
  • Page 93 Bosch Sicherheitssysteme GmbH Bosch Security Systems, Inc Robert-Bosch-Ring 5 1706 Hempstead Road 85630 Grasbrunn Lancaster, PA, 17601 Germany www.boschsecurity.com © Bosch Sicherheitssysteme GmbH, 2017...

This manual is also suitable for:

Mic ip fusion 9000i

Table of Contents