Product Information

2
Product Information
Heat pump AW OR together with the Pre plumbed cylinder indoor unit is
part of a series of heating systems that use outdoor air to provide energy
for water transferred heat and domestic hot water.
The heating system is controlled by a central controller which is located
in the indoor unit. The user interface manages and supervises the
system with different settings for heat, cold, hot water and other
operations. The monitoring function will e.g. turn off the outdoor unit in
case of disturbances to avoid damage to vital components.
2.1

Protection zone

The product contains the refrigerant R290 that has a density greater
than air. If a leak occurs, the refrigerant could accumulate near the
ground. The refrigerant must therefore be prevented from collecting in
drains, gaps, other sinks, hollows or depressions in the building.
No building openings such as light shafts, hatches, valves, open down
pipes, cellar entrances, windows, doors, roof vents and roof drainage
systems, pump shafts, inlets in sewers, waste water shafts, etc. are
permitted within the defined protection zone around the product. The
protection zone must not overlap general areas or adjacent plots.
No sources of ignition such as contactors, lamps or electrical switches
are permitted within the protection zone. The defined protection zones
are also applicable for installations on pitched roofs, with the addition
that no openings to the building and no sources of ignition are allowed
below the product.
No structural changes are allowed in the protection zone that violates the
rules mentioned above for the protection zone.
2.1.1

Protection zone, ground-placed heat pump by wall

A
A
B
Fig. 1
Protection zone ground-placed
[A]
1000 mm
[B]
1000 mm
4
A
0010037106-006
2.1.2
Protection zone, ground-placed heat pump free standing or
on a flat roof
A
Fig. 2
Protection zone ground-placed on plot or roof
[A]
1000 mm
[B]
1000 mm
[F]
Front
2.1.3
Protection zone, ground-placed heat pump in a corner
Fig. 3
Protection zone ground-placed in a corner
[A]
1000 mm
[B]
2000 mm
2.2

Data plate

• The data plate is located on the RH side of the control box. For the
exact location ( the installation instructions of the appliance).
The data plate contains information on output, item number, serial
number and date of manufacture.
2.3

Declaration of Conformity

The design and operating characteristics of this product comply with the
British, European and supplementary national requirements.
The UKCA and CE markings declare that the product
complies with all the applicable British and
European legislation, which is stipulated by
attaching these markings.
You can request the complete text of the Declaration of Conformity from
the UK address indicated in this document.