Explanation of symbols and safety instructions

1.1

Explanation of symbols

Warnings
In warnings, signal words at the beginning of a warning are used to
indicate the type and seriousness of the ensuing risk if measures for
minimizing danger are not taken.
The following signal words are defined and can be used in this document:
DANGER
DANGER indicates that severe or life-threatening personal injury will
occur.
WARNING
WARNING indicates that severe to life-threatening personal injury may
occur.
CAUTION
CAUTION indicates that minor to medium personal injury may occur.
NOTICE
NOTICE indicates that material damage may occur.
Important information
The info symbol indicates important information where there is no risk to
people or property.
Additional symbols
Symbol
Meaning
a step in an action sequence
a reference to a related part in the document
a list entry
a list entry (second level)
Table 1
1.2

General safety instructions

1.2.1

Application area

The heat pump may only be used in sealed heating systems according to
EN 12828.
Other uses are not appropriate. Any damage that results from such use is
excluded from liability.
The heat pump must undergo maintenance according to EN1717 4.6.
HSafety of electrical devices for domestic use and similar
purposes
The following requirements apply in accordance with EN 60335-1 in
order to prevent hazards from occurring when using electrical
appliances:
"This appliance can be used by children of 8 years and older, as well as
by people with reduced physical, sensory or mental capabilities or
lacking in experience and knowledge, if they are supervised and have
been given instruction in the safe use of the appliance and understand
the resulting dangers. Children shall not play with the appliance.
Cleaning and user maintenance must not be performed by children
without supervision."
Compress 5800iAW 12 E | OR-S | T – 6721871228 (2023/06)
Explanation of symbols and safety instructions
"If the power cable is damaged, it must be replaced by the manufacturer,
its customer service department or a similarly qualified person, so that
risks are avoided."
HDanger of fire or explosion of flammable gases
The product contains the flammable refrigerant R290. If a leak occurs,
the refrigerant may form a combustible gas due to mixing with air. There
is a risk of fire and explosion.
A protection zone is defined around the product; see the "Protection
zone" chapter.
▶ Make sure that no sources of ignition are present near the protection
zone, especially open fires, surfaces hotter than 370 °C, spray or
other gases that could ignite.
HInspection and maintenance
If there is a lack of cleaning, inspection or maintenance, or if these are
carried out incorrectly, this may result in material damage and/or
personal injury, including possible risk to life.
▶ Have work carried out only by an approved contractor.
▶ Do not take off the heat pump cover.
▶ Do not modify the heat pump or other parts of the heating system.
HRoom air
The air in the installation room must be free of combustible or chemically
aggressive substances.
▶ Do not use or store combustible or explosive materials (paper,
propellants, thinners, paints, etc.) within the vicinity of the
appliance.
▶ Do not use or store corrosive substances (solvents, adhesives,
chlorinated cleaning agents, etc.) within the vicinity of the appliance.
HDamage caused by frost
The solar system can freeze if it is switched off:
▶ Observe the notices regarding frost protection.
▶ Due to the additional functions, e.g. DHW heating or pump anti-
seizure protection, the system should always be left on.
▶ Correct any faults immediately.
HRisk of scalding at the DHW draw-off points
▶ If DHW temperatures above 60 °C are set or if thermal disinfection is
activated, a mixer must be installed. If in doubt, ask your installer.
2

Product description

Heat pump AW OR is included with the unit Compress 5800i 12 E in a
series of heating pumps that extract energy from the outdoor air to
provide water-borne heat and hot water. By turning the process over and
taking up heat from the water and placing it in the outdoor air, the plant
can produce cooling if necessary. However, this requires that the heating
system is intended for cooling operation.
The heating system is controlled by a control unit located in the inside
unit. The control unit controls and monitors the system with the help of
various settings for heating, cooling, hot water and other operations. The
monitoring function closes e.g. of the outdoor unit in case of any
malfunctions so that no vital parts are damaged.
2.1

Protection zone

The product contains the refrigerant R290 that has a density greater
than air. If a leak occurs, the refrigerant could accumulate near the
ground. The refrigerant must therefore be prevented from collecting in
niches, drains, gaps, other sinks, hollows or depressions in the building.
No building openings such as light shafts, hatches, valves, open down
pipes, cellar entrances, windows, doors, roof vents and roof drainage
systems, pump shafts, inlets in sewers, waste water shafts, etc. are
permitted within the defined protection zone around the product. The
protection zone must not overlap general areas or adjacent plots.